1-10
System Overview
Table 1-4. System Status Abnormal Conditions
Status LED
Description
Response
Off
POST is in progress.
Wait for a while. It lights in green a few seconds after
completion of POST.
CPU error is detected.
Turn the server off and then back on. If an error
message appears during POST, take note of the error
message and contact your technical support
representative.
CPU temperature error is detected.
(Thermal-Trip)
Same
Watchdog timer has timed out.
Same
Uncorrectable error is detected in the
memory.
Same
PCI system error is detected.
Same
PCI parity error is detected.
Same
CPU bus error is detected.
Same
Memory dump request is being
issued.
Wait until the memory dump finishes.
Green
(Flashing light)
Memory or CPU is degraded.
Use the BIOS setup utility, SETUP, to locate the
degraded device and replace it as soon as possible.
Amber
(Steady light)
Temperature error is detected.
Check if any fan inside the server has dust on it. Make
sure that fan cables are firmly connected.
If the lamp indication still does not change, contact
your technical support representative.
Voltage error is detected.
Contact your technical support representative.
All power units failed.
Contact your technical support representative.
Installation error is detected on a
CPU, CPU termination board, or PCI
board.
Re-install the suspected device.
Processor cover removed.
Re-install the processor cover.
Amber
(Flashing light)
Redundant power error is detected.
Contact your technical support representative.
Fan alarm is detected.
Make sure fan cables are firmly connected.
If they are and the lamp indication still does not
change, contact your technical support representative.
Temperature alarm is detected.
Check if any fan inside the server has dust on it. Make
sure that fan cables are firmly connected.
If the lamp indication still does not change, contact
your technical support representative.
Voltage alarm is detected.
Contact your technical support representative.
Fan module removed.
Check that the fan modules are properly installed.
Red
(Steady light)
RAS controller error is detected.
Contact your technical support representative.
Summary of Contents for EXPRESS5800/120Md Series
Page 1: ... U s e r s G u i d e EXPRESS5800 120Md ...
Page 2: ...NEC ...
Page 3: ... U s e r s G u i d e EXPRESS5800 120Md ...
Page 58: ...2 16 Setting Up the System Figure 2 10 Connecting the AC Power Cord to the Server ...
Page 64: ...2 22 Setting Up the System ...
Page 92: ...3 28 Configuring Your System ...
Page 165: ...A Technical Specifications Server Unit ...
Page 168: ...A 4 Technical Specifications ...
Page 174: ...B 6 Interrupt Request PCI IRQ Device I O Port Address Assignments ...
Page 185: ...D ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes ...
Page 188: ...D 4 ROMPilot BIOS Error Codes ...
Page 198: ...10 Glossary ...
Page 204: ...Index 4 ...
Page 205: ...xx ...
Page 206: ... 456 01557 N00 ...