Configuring Your Server 4-23
Server
The Server menu appears if you move the cursor to "Server."
See the table below for the items.
Option
Parameter
Description
Your Setting
Assert NMI on
SERR
Disabled
[Enabled]
Indicates whether PCI SERR is
supported or not.
Post Error Pause
Disabled
[Enabled]
Indicates whether POST is aborted once
at the end of POST if an error occurs
during the execution of POST.
AC LINK
Stay Off
[Last State]
Power On
Indicates the AC LINK function. Shows
the state of the power of the server.
[ ]: Factory-set
IMPORTANT:
To power on the server from the UPS (Uninterruptible Power
Supply), select [Server] - [AC Link] - [Power On].
If the server is connected to the UPS, set at least 10 seconds delay in
the power-on schedule.
The table below shows the operation when the AC power to the server is turn off once and then on
again, depending on the setting of "AC LINK."
Setting of AC LINK
System status before AC power off
Stay Off
Last State
Power On
Operating
Off
On
On
Aborting (DC power being off also)
Off
Off
On
Forced shutdown
Off
Off
On
* Press the power switch continuously for four seconds or longer. This forcibly turns off the
power.
Summary of Contents for Express5800/110Ei
Page 16: ...x This page is intentionally left blank ...
Page 33: ...General Description 2 5 Rear View 1 2 3 2 4 5 6 7 8 9 10 11 12 ...
Page 104: ...4 42 Configuring Your Server This page is intentionally left blank ...
Page 148: ...5 44 Installing the Operating System with Express Setup This page is intentionally left blank ...
Page 168: ...6 20 Installing and Using Utilities This page is intentionally left blank ...
Page 180: ...7 12 Maintenance This page is intentionally left blank ...
Page 270: ...10 14 Internal Cabling Diagrams This page is intentionally left blank ...
Page 272: ...A 2 Specifications This page is intentionally left blank ...
Page 314: ...F 4 Product Configuration Record Table This page is intentionally left blank ...