RC40 Control manual
100
default value is;
2.80% motor load is too large;
2.Replace the more
powerful motor;
e0xFF32
Regeneration
braking overload
warning
Energy consumption braking
resistor power is too small;
Replace the more powerful
energy consumption braking
resistor;
e0xFF33
Speed limited due
to undervoltage
warning
Due to the drive input power
supply voltage is too low
motor speed is limited;
Check the input voltage;
e0xFF34
DC bus
undervoltage
warning
Dc bus voltage is too low;
Check the dc bus voltage;
e0xFF35
HIstorical fault
record missing
warning
1.History fault record
abnormal;
2.Drive damage;
1.Restart the drives or soft
reset;
2.Repair or replace the
drive
e0xFF36
Unsupported
operation mode
Drive control mode setting
exceeds the allowed range;
Reset parameter 0x6060;
e0xFF37
Power-on effective
parameters
changed
Changed the parameters of
repower availability
Restart the drive or soft
reset;
e0xFF38
CPU overload
warning
Internal drive failure
Replace or repair drivers;
e0xFF39
Encoder battery
undervoltage
warning
Low encoder battery voltage
detected;
Replace the encoder
battery;
e0xFF3A
Drive internal
warning
The drive has not passed the
factory test;
Replace the drive;