NAL Research Corporation (451-93156-009A)
97
APPENDIX D: INFORMATIVE EXAMPLES
The examples below are presented in two different formats. The format used in each example has no
significance. A single format will be used in a future revision of this document.
D.1 Unit Identification
When beginning to build a communication link, a general DTE application controlling the A3LA-RG
should confirm the type of Iridium device to which it is connected.
D.2 Setting the Default Configuration
The DTE sets the A3LA-RG’ default configuration to no flow control, SBD automatic notifications enabled.
D.3 Power-on to Sending an SBD Message
The DTE will power up the A3LA-RG, wait for the A3LA-RG to acquire the network, and send a 70-byte
message.
To A3LA-RG
(from DTE)
To DTE (from A3LA-RG)
Description
AT+CGMI
Get manufacturer name
Iridium
OK
AT+CGMM
Get model number
<model ID>
OK
AT+CGMR
Get revision
Call processor version: <revision>
DSP version: <revision>
…
OK
AT+CGSN
Get IMEI
300001000000000
OK
To A3LA-RG
(from DTE)
To DTE (from A3LA-RG)
Description
AT&K0
Disable RTS/CTS flow control
OK
AT+SBDMTA=1
Enable SBD ring indications
OK
AT&W0
Store the configuration as profile 0
OK
AT&Y0
Select profile 0 as the power-up
default
OK