112305 – HI T-Exhaust A5
Yellow alarm. Initiated by EMU.
Cause
Corrective action
The exhaust temperature of this
cylinder is too high as compared
with the average value.
1. Check emission values.
2. Check ignition timing (→ Page 137).
3. Check valve drive (exhaust valves do not close).
112306 – HI T-Exhaust A6
Yellow alarm. Initiated by EMU.
Cause
Corrective action
The exhaust temperature of this
cylinder is too high as compared
with the average value.
1. Check emission values.
2. Check ignition timing (→ Page 137).
3. Check valve drive (exhaust valves do not close).
112307 – HI T-Exhaust A7
Yellow alarm. Initiated by EMU.
Cause
Corrective action
The exhaust temperature of this
cylinder is too high as compared
with the average value.
1. Check emission values.
2. Check ignition timing (→ Page 137).
3. Check valve drive (exhaust valves do not close).
112308 – HI T-Exhaust A8
Yellow alarm. Initiated by EMU.
Cause
Corrective action
The exhaust temperature of this
cylinder is too high as compared
with the average value.
1. Check emission values.
2. Check ignition timing (→ Page 137).
3. Check valve drive (exhaust valves do not close).
112309 – HI T-Exhaust A9
Yellow alarm. Initiated by EMU.
Cause
Corrective action
The exhaust temperature of this
cylinder is too high as compared
with the average value.
1. Check emission values.
2. Check ignition timing (→ Page 137).
3. Check valve drive (exhaust valves do not close).
112310 – HI T-Exhaust A10
Yellow alarm. Initiated by EMU.
Cause
Corrective action
The exhaust temperature of this
cylinder is too high as compared
with the average value.
1. Check emission values.
2. Check ignition timing (→ Page 137).
3. Check valve drive (exhaust valves do not close).
MS150059/01E 2012-07 | Troubleshooting | 53
TIM-ID: 0000017543 - 001