Information pertaining to alarm colors and automatic engine shutdown in the fault code list refer to the
(default) factory settings of the engine governor on delivery. Different system response may be possible
due to changes to the genset control system made by the OEM (see documentation of the genset manu‐
facturer).
Only persons with a corresponding qualification/training at MTU are allowed to carry out the measures
listed below.
Contact Service should troubleshooting as prescribed in the fault code list prove unsuccessful.
Recommended action in case of alarm
Yellow alarm:
The engine can still be operated providing that automatic engine shutdown to protect the engine has not
been configured or is not tripped. Contact Service immediately/start fault rectification.
Red alarm:
Caution, the engine is running at its limits. Shut down manually without further delay if the engine does
not shut itself down immediately after a red alarm is signaled.
SE (System Error) alarms
SE No.
Fault message text
0
Sensor Temperature Defect
1
Temperature failure
2
Sensor Voltage Defect
3
Voltage failure
4
CAN Bus- 1 Error/Bus Defec
5
CAN Bus- 1 Overrun
6
CAN Bus- 2 Error/Bus Defec
7
CAN Bus- 2 Overrun
8
Temperature Compensation Error
9
I/O-Module Slot2 Defect
10
I/O-Module Slot3 Defect
11
I/O-Module Slot4 Defect
12
Serial Connection Lost
13
CAN Bus- 3 Error/Bus Defec
14
CAN Bus- 3 Overrun
15
S/A Bus Faulty
16
PAN 1 Defect
17
PAN 2 Defect
18
PAN 3 Defect
19
PAN 4 Defect
20
PAN 5 Defect
21
PAN 6 Defect
22
I/O-Module Slot1 Defect
23
I/O-Module Slot5 Defect
24
I/O-Module Slot6 Defect
25
I/O-Module Slot7 Defect
50 | Troubleshooting | MS150059/01E 2012-07
TIM-ID: 0000017545 - 001