Power Connection
The power cord should be plugged into an easily accessible
outlet. The built-in power supply automatically adjusts to any
outlet, providing it is between 90 VAC and 264 VAC at 50/60 Hz.
{
XE "Power connection"
}
The power cord used for a 115 Volt configuration is a
minimum-type SJT (SVT) 18/3, rated 250 VAC, 10 Amps with a
maximum length of 15 feet. One end terminates in an IEC 320
attachment plug, the other end terminates in a NEMA 5-15P plug.
The power cord used for a 230 volt configuration is a
minimum-type SJT (SVT) 18/3, rated 250 VAC, 10 Amps with a
maximum length of 15 feet. One end terminates in an IEC 320
attachment plug, the other end terminates as required by the
country where it is installed.
Installation and Wiring
You must check the nameplate rating on the unit to ensure that
there is no overloading of supply circuits that could effect
overcurrent protection and supply wiring.
{
XE "Wiring conditions"
}
48-volt DC-rated equipment must be installed according to the
following conditions:
■
Connect to a supply source that is electrically isolated from the
alternating current source. The 48-volt DC source should be
connected to a 48-volt DC SELV source.
■
Input wiring to a terminal block must be routed and secured so
that it is protected from damage and stress. Do not route wiring
past sharp edges and/or moving parts.