EM316LNXNM-OT
SNMP Management
PN 1275005-100 Rev E6
100
Completely disable trap generation by removing all IP addresses from the SNMP trap table:
fiberdriver(config)# no snmp-server host
fiberdriver(config)#
Selectively disable specific traps with the "
no gen-trap
" command, found in the chassis 1 config
context:
fiberdriver(chassis/1)# no gen-trap chassis
fiberdriver(chassis/1)# no gen-trap lin
fiberdriver(chassis/1)# no gen-trap link
fiberdriver(chassis/1)# no gen-trap loopback
fiberdriver(chassis/1)# show
Model: EM316-16BU
Name: EM316-16
Temp(C): 23
Temp Min(C): 5
Temp Limit(C): 40
PS1: DC Bad
PS2: AC Good
Fan1: good Fan3: good
Fan2: good Fan4: not Installed
Chassis Traps: off Slot Change Traps: on Module Specific Traps: on
Port Traps: on Link Traps: off Loopback Traps: off
LIN Traps: off Port Change Traps: on Port Diags Traps: on
Number Of Slots: 16
Slot Model Name
==== ============= ============================
1.3 EM316-LNXNM12 Slot 1 (EM316-LNXNM12 at 1.3)
fiberdriver(chassis/1)#