UFM091
6.4 U
se
6.4.1 Installation
The mobile filtration unit must be positioned in a place that guarantees its stability during use.
TRANSFER
Connect/immerse the metal suction lance (IN) to the tank or to the drum, immerse the discharge hose (OUT) in the machine tank
or in the drum which should be transferred to.
If the transfer oil has to be cleaned, it is advisable to filter the oil contained in the drum or tank several times before being transferred.
In this case immerse the metal suction lances (IN) and the discharge lances (OUT) in the drum or oil tank to be transferred. Be
careful that the lances remain below the level of the oil to be transferred in order to avoid foaming and cavitation; space the ends
of the two lances as far as possible from each other in order to recirculate all the fluid and not generate an emulsion.
FILTRATION
Immerse the metal suction lances (IN) and the discharge lance (OUT) inside the tank far from each other, possibly positioning them
at different heights (100 mm suction from the bottom of the tanks, immersed flow for a minimum of 200 mm).
Make sure that the tubes/lances are properly fixed or perfectly stable before starting.
Be careful not to mix up the suction and discharge hoses. The suction hose (IN) is the one with the largest diameter.
The discharge lance must in general have unrestricted flow. It is prohibited to install taps or components on both
hoses that may obstruct or reduce the flow of the fluid.
CAUTION
!
6.4.2 Power on
Insert the electric plug into a three-phase socket (Fig. 6) depending on the version (check the voltage).
Check the direction of rotation in the version with three-phase motor: Operate the switch for a few seconds and observe the
direction of rotation of the electric motor. The direction observed on the fan side must be clockwise, otherwise the phases L1 and
L2 must be inverted (Fig. 7).
Three-phase electric power supply with protective conductor is required for the power supply of the trolley.
NOTE
Electrical connection for the
three-phase motor
(5 poles plug)
Phase inverter only for
version with ICM2.0 particle
counter
Fig.6
Fig.7
Operate the switch for a few seconds and observe the direction of rotation. The direction observed on the fan side
must be clockwise, otherwise the phases L1 and L2 must be inverted.
NOTE
CAUTION
!
Before starting up the electric motor, make sure that the suction lance (IN) is immersed in the fluid.
5 poles plug for the three-phase motor
Mobile filtration unit
79
Summary of Contents for UFM Series
Page 1: ...Use Maintenance Manual UFM Series Mobile transfer and filtration unit ...
Page 2: ......
Page 4: ...Mobile filtration unit 2 ...
Page 11: ...GENERAL WARNINGS Mobile filtration unit 9 ...
Page 12: ...Mobile filtration unit 10 ...
Page 14: ...Mobile filtration unit 12 ...
Page 18: ...Mobile filtration unit 16 ...
Page 20: ...5 1 Dimensions Mobile filtration unit 18 ...
Page 30: ...Mobile filtration unit 28 ...
Page 32: ...5 1 Dimensions Drain valve Mobile filtration unit 30 ...
Page 44: ...Mobile filtration unit 42 ...
Page 65: ...UFM051 Mobile filtration unit 63 ...
Page 72: ...Mobile filtration unit 70 ...
Page 74: ...5 1 Dimensions Drain tube Mobile filtration unit 72 ...
Page 89: ...UFM091 Mobile filtration unit 87 ...
Page 93: ...UFM091 Mobile filtration unit 91 ...
Page 94: ...Mobile filtration unit 92 ...
Page 96: ...5 1 Dimensions Drain tube Mobile filtration unit 94 ...
Page 109: ...UFM181 Mobile filtration unit 107 ...
Page 113: ...UFM181 Mobile filtration unit 111 ...
Page 114: ...Mobile filtration unit 112 ...
Page 116: ...5 1 Dimensions Drain tube Mobile filtration unit 114 ...
Page 129: ...UFM919 Mobile filtration unit 127 ...
Page 133: ...UFM919 Mobile filtration unit 131 ...
Page 135: ......