6.6 Filter clogging
-
Versions with visual differential clogging indicator
UFM051MA2010P01 - UFM051TA2010P01 - UFM051MA2020P01 - UFM051TA2020P01
The conditions relating to the blockage of the filter element are guaranteed by a visual indicator (Fig. 23) mounted on the head of
the LMP430 filter. When the differential pressure of 3 bar is reached, the red alarm piston is visible.
Replace the filter element.
-
Versions with electric/visual differential pressure indicator for blockage
UFM051MA3010P01 - UFM051TA3010P01 - UFM051MA3020P01 - UFM051TA3020P01 - UFM051TA3021P01
The conditions related to the blockage of the filter element are ensured by an electric indicator (Fig. 24) mounted on the head of
the LMP430 filter. When the differential pressure of 3 bar is reached, the electric signal switches off the machine and turns on the
light on the electrical panel. Replace the filter element.
All models are equipped with a pressure gauge (Fig. 25) with 10 bar full scale to measure the circuit pressure.
For signalling the clogged filter, refer to the differential pressure indicators.
The LMP430 filter is equipped with a bypass valve with a response pressure set at 3.5 bar.
It is recommended to never exceed the response pressure of the bypass valve (3.5 bar).
CAUTION
!
Version with visual/
electric indicator
Pressure gauge
Version with visual
indicator
Fig.23
Fig.24
Fig.25
6.6.1 Replacing the filter element
Before proceeding with the replacement of the filter element, make sure that the oil temperature is lower than +40/45° C.
Replace the filter element whenever necessary, i.e. whenever the differential pressure indicator indicates a clogged filter or when
different fluids must be filtered.
The filtration of the filter element takes place from the outside to the inside, drain the residual oil into the body as it is not normally
clean.
The oil must always be emptied using the drain valve (Fig. 26) located at the base of the filter body, clean the inside of the container.
Mobile filtration unit
60
Summary of Contents for UFM Series
Page 1: ...Use Maintenance Manual UFM Series Mobile transfer and filtration unit ...
Page 2: ......
Page 4: ...Mobile filtration unit 2 ...
Page 11: ...GENERAL WARNINGS Mobile filtration unit 9 ...
Page 12: ...Mobile filtration unit 10 ...
Page 14: ...Mobile filtration unit 12 ...
Page 18: ...Mobile filtration unit 16 ...
Page 20: ...5 1 Dimensions Mobile filtration unit 18 ...
Page 30: ...Mobile filtration unit 28 ...
Page 32: ...5 1 Dimensions Drain valve Mobile filtration unit 30 ...
Page 44: ...Mobile filtration unit 42 ...
Page 65: ...UFM051 Mobile filtration unit 63 ...
Page 72: ...Mobile filtration unit 70 ...
Page 74: ...5 1 Dimensions Drain tube Mobile filtration unit 72 ...
Page 89: ...UFM091 Mobile filtration unit 87 ...
Page 93: ...UFM091 Mobile filtration unit 91 ...
Page 94: ...Mobile filtration unit 92 ...
Page 96: ...5 1 Dimensions Drain tube Mobile filtration unit 94 ...
Page 109: ...UFM181 Mobile filtration unit 107 ...
Page 113: ...UFM181 Mobile filtration unit 111 ...
Page 114: ...Mobile filtration unit 112 ...
Page 116: ...5 1 Dimensions Drain tube Mobile filtration unit 114 ...
Page 129: ...UFM919 Mobile filtration unit 127 ...
Page 133: ...UFM919 Mobile filtration unit 131 ...
Page 135: ......