F01
Range
Default
F01.007 Switch Condition 1
F01.008 Switch Condition 2
F01.009 Switch Condition 3
F01.010 Switch Condition 4
Are automatically set by the
assignment screen of OS3.2 and
should not be modified
F01.011 Switch on Delay
Delay time between event appearance and
switching response of Function 1.
0 = immediate response
0.000 … 9.999
(sec.)
0.000
F01.012 Pulse Time
Duration time of Switching Function 1
0 = static operation
0.000 … 9.999
(sec.)
0.000
Lock Function
0= Normal function (no catch)
F01.013
1= Catch function: Once Function 1 is activated
only the external command “Release Function”
or power off can clear the switching state
0 … 1
0
Polarity
F01.014
0= True Events set Function 1 to ON
0 … 1
0
1= True Events set Function 1 to OFF
6.2.2.
Settings for Switching Function 2 (Description see Function 1)
F02
Range
Default
F02.016 Set Speed 1.1
0 … 999 999
12001
F02.017 Set Speed 1.2
0 … 999 999
12002
F02.018 Set Speed 2.1
0 … 999 999
22001
F02.019 Set Speed 2.2
0 … 999 999
22002
F02.020 Setpoint Counter 1
0 … 999 999
32000
F02.021 Setpoint Counter 2
0 … 999 999
42000
F02.022 Differential Setpoint
0 … 999 999
52000
F02.023 Switch Condition 1
F02.024 Switch Condition 2
F02.025 Switch Condition 3
F02.026 Switch Condition 4
Are set by the assignment
screen of OS3.2 and should not
be modified
F02.027 Switch on Delay
0.000 … 9.999
0.000
F02.028 Pulse Time
0.000 … 9.999
0.000
F02.029 Lock Function
0 … 1
0
F02.030 Polarity
0 … 1
0
Summary of Contents for MM 640