MM64003a_e.doc / Feb-09
Page 32 / 44
6.2.10.
Serial communication settings
F09
Range
Default
F09.128 Unit Number
11 … 99
11
F09.129 Serial Baud Rate
0 … 6
0
0= 9600 Baud
1= 4800 Baud
2= 2400 Baud
3= 1200 Baud
4= 600 Baud
5=
19200
Baud
6=
38400
Baud
F09.130 Serial Format
0 … 9
0
0= 7 Data, Parity even, 1 Stop
1= 7 Data, Parity even, 2 Stop
2= 7 Data, Parity odd, 1 Stop
3= 7 Data, Parity odd, 2 Stop
4= 7 Data, no Parity, 1 Stop
5= 7 Data, no Parity, 2 Stop
6= 8 Data, Parity even, 1 Stop
7= 8 Data, Parity odd, 1 Stop
8= 8 Data, no Parity, 1 Stop
9= 8 Data, no Parity, 2 Stop
Summary of Contents for MM 640