MM64003a_e.doc / Feb-09
Page 14 / 44
4.
Setup of the Unit by PC
4.1.
PC connection
For initial setup of the MM640 Motion Monitor a PC with the motrona OS32 operator software
is required (Software version OS32_1t or higher). This software is included on CD and is also
available for free download from our homepage
www.motrona.com
.
The software allows to set all basic parameters and to assign the desired switching functions
to the outputs. During later operation, the four programming keys on the front side of the unit
can be used to change settings like Setpoints or scaling parameters (see 5.).
Connect your PC to the monitor as shown in chapter 2.7 and start the OS32 software.
The adjoining screen will appear.
If your text and color fields remain empty and the headline says „OFFLINE“, you must verify
your serial settings. To do this, select “Comms“ from the menu bar.
•
Ex factory, all motrona units use the following serial standard settings:
Unit No. 11, Baud rate 9600, 1 start/ 7 data/ parity even/ 1 stop bit
•
If the serial settings of your unit should be unknown, you can run the
“SCAN“ function from the „TOOLS“ menu to find out.
4.2.
The Main Screen
The edit window for all unit parameters can be found on the left side of the screen.
To enter your parameters, please click to the corresponding line, enter a new value and save
the new value by pressing ENTER on your PC keyboard.
You can also just change all digits according to need, then finally click to the Softkeys
“Transmit All” followed by “Store EEProm” to save all your settings.
The INPUTS field provides Softkeys to switch the control commands on or off.
Display boxes in the RS column indicate when the corresponding command is set to ON by PC.
Display boxes in the PI/O column indicate that commands assigned to the hardware inputs
(input1 to input4) are switched ON by external signal.
The OUTPUT field informs about the actual state of the four outputs and the four relays.