MM64003a_e.doc / Feb-09
Page 29 / 44
6.2.7.
Encoder 2 Settings (Description see “Encoder 1 Settings”)
F07
Range
Default
F07.091 Factor Counter 2
0.00001 … 9.99999 1.00000
F07.092 Multi. Counter 2
1 … 99
1
F07.093 DP Counter 2
0 … 5
0
F07.094 Dir Window Counter 2
1 … 99
4
F07.095 Multi. Speed 2
0 … 999 999
1
F07.096 Divi. Speed 2
0 … 999 999
1
F07.097 Offset Speed 2
-99 999 … 99 999
0
F07.098 DP Speed 2
0 … 5
0
F07.099 Sampling Time 2
0.001 … 9.999
0.010
F07.100 Wait Time 2
0.001 … 9.999
0.100
F07.101 Filter 2
0 … 4
0
F07.102 Encoder Properties 2
0 … 3
1
F07.103 Edge Counting 2
0 … 2
0
F07.104 Counting Direction 2
0 … 1
0
6.2.8.
Key command assignments
F08
Range
Default
F08.106 Key UP Action
0 … 15
0
0=
No
function
1= Reset counter 1 (encoder 1)
2= Reset counter 2 (encoder 2)
3=
Reset
difference
[
counter1 - counter2]
4=
Scroll
Display
5=
n.
a.
6=
n.
a.
7=
Store
EEProm
8=
Release
Function
Lock
9=
Freeze
Functions
For more details about these
functions see section 7.
F08.107 Key Down Action
0 … 15
0
See key „UP“
F08.108 Key Enter Action
0 … 15
0
See key „UP“
n.a. = not applicable
Summary of Contents for MM 640