6.2.11.
Special Functions
F10
Range
Default
F10.134 Input filter: must be set to “0”.
0 … 3
0
F10.135 Trigger Threshold 1 for encoder1 inputs *)
30 … 250
166
F10.136 Trigger Threshold 2 for encoder2 inputs *)
30 … 250
166
F10.137 Brightness of the 7-segment LED display
0 … 4
0
0= 100% of maximum brightness
1= 80% of maximum brightness
2= 60% of maximum brightness
3= 40% of maximum brightness
4= 20% of maximum brightness
F10.138 Display Time: Update time (sec.) for display only
0.005 … 9.999
0.050
F10.139 Frequency Control must be set to “0”
0 … 1
0
F10.140 Power Down (date retention of actual counter
values in case of power-down)
0 … 1
0
0= No retention of positional and differential
counters, Restart with zero upon power-up
1= Actual values of positional and differential
counters are retained after power-down
*) Must be set to the default value (166) for any kind of input signals, except for single-
ended TTL signals which require a setting of 35.
•
Since some of above parameters are not for customer use, and to avoid
accidental change of settings, above menu is protected by password (see 6.2.12)
6.2.12.
Keypad protection codes
F11
Range
Default
F11.143 Protect group F01
0
F11.144 Protect group F02
0
F11.145 Protect group F03
0 = no protection
0
F11.146 Protect group F04
0
F11.147 Protect group F05
1 – 999 999 =
0
F11.148 Protect group F06
Protection code
0
F11.149 Protect group F07
for the actual
0
F11.150 Protect group F08
parameter group
0
F11.151 Protect group F09
0
F11.152 Protect group F10
6078
F11.153 Protect group F11
6078