1. Select the
All Heads
tab to adjust the settings that apply to the whole camera. These settings include
Flicker Control and Enable WDR on the Image and Display page, as well as Saturation, Brightness,
Sharpness and Contrast on the Image and Display > Adjustments page.
2. In the All Heads tab, you can set the
Imaging mode
:
l
Select
Global
to apply the same settings to all camera heads. Use the settings listed in the All
Heads tab to adjust the camera image settings. The same settings for each numbered Head
tab are disabled.
l
Select
Per-head
to apply different settings to each camera head. Select the different tabs to
change the settings for each camera head.
3. Select each numbered tab to adjust the focus controls for each camera head. These settings must be
manually adjusted for each camera head.
For more information about the different Image and Display settings, see
.
For more information about enabling and disabling an H4 Multisensor IR LEDs, see
.
Enabling and Disabling IR LEDs
The IR LED Ring page is used to enable and disable the individual IR LEDs on the optional IR LED Ring
(H4AMH-AD-IRIL1) for the H4 Multisensor camera. Depending on the placement and use of the H4
Multisensor camera, it may be necessary to disable some of the IR LEDs on the IR LED Ring. Disabling IR
LEDs can avoid issues such as IR light reflecting off of windows and other reflective surfaces.
1. In the left-menu page, navigate to the IR LED Ring page.
2. Select or clear the check box for each individual IR LED, from LED 1 to LED 6 to enable or disable the
selected LED.
3. Click
Apply
to save your changes.
IR LED Ring Health Check
The IR LED Ring page also provides health status information for the IR LED ring. The IR LED ring health
check is enabled by default.
l
You can enable or disable the health check by selecting or clearing the
Enable IR LED Ring Health
Check
checkbox. Click
Apply
to save your changes.
When health checking is enabled, the application will monitor communication with each of the LEDs every
15 seconds. The following status messages may be displayed in the
IR LED Ring Status
field:
l
Health Check disabled
. Indicates that the IR LED ring health check has been disabled.
l
No error detected
. Indicates that the IR LED ring is functioning normally.
l
Unplugged
. Indicates that no IR LED ring is connected to this camera. If an IR LED ring will not be
connected, consider disabling the Enable IR LED Ring Health Check checkbox.
l
Error detected in IR ring and power has been disabled. Reboot the camera
Enabling and Disabling IR LEDs
48