background image

Surveyor Central   

 

1-10 

 

 

 

 

Warranty 

Mortara Instrument, Inc. warrants that Mortara products shall be free from defects in material and 
workmanship under normal use, service and maintenance for one year of such Product from Mortara or 
an authorized distributor or representative of Mortara. Normal use, service and maintenance means, 
operation and maintenance in accordance with appropriate instructions and/or information guides. This 
Warranty does not apply to damage to the Products caused by any or all of the following circumstances 
or conditions: 

 

(a.) 

Freight damage; 

(b.) 

Parts and/or accessories of the Products not obtained from or approved by Mortara; 

(c.) 

Misapplication, misuse, abuse and failure to follow the Product instruction sheets and/or 

information guides; 

(d.) 

Accident, a disaster affecting the Products; 

(e.) 

Alterations or modifications to the Products not authorized by Mortara; 

(f.) 

Other events outside of Mortara’s reasonable control or not arising under normal operating 

conditions. 

 

The remedy under this warranty is limited to the repair or replacement without charge for labor or 
materials, of any Products found upon examination by Mortara to have been defective. This remedy shall 
be conditioned upon receipt of notice by Mortara of any alleged defects promptly after discovery thereof 
within the warranty period. Mortara’s obligations under the foregoing warranty will further be conditioned 
upon the assumption by the purchase of the Products (i) of all carrier charges with respect to any 
Products returned to Mortara’s principal place or any other place as specifically designated by Mortara or 
an authorized distributor or representative of Mortara, and (ii) all risk of loss in transit. It is expressly 
agreed that the liability of Mortara is limited and that Mortara does not function as an insurer.  A 
purchaser of a Product, by its acceptance and purchase thereof, acknowledges and agrees that Mortara 
is not liable for loss, harm or damage due directly or indirectly to an occurrence or consequence there 
from relating to the Products. If Mortara should be found liable to anyone under any theory (except the 
expressed warranty set forth herein) for loss, harm or damage, the liability of Mortara shall be limited to 
the lesser of the actual loss, harm or damage, or the original purchase price of the Product when sold. 

 

Excluded from the limited warranty set forth above are consumable items such as, but not limited to; 
paper, batteries, electrodes, patient cables, lead wires, and magnetic storage mediums. 

 

Except as set forth herein with respect to reimbursement of labor charges, a purchaser’s sole exclusive 
remedy against Mortara for claims relating to the products for any and all losses and damages resulting 
from any cause shall be the repair or replacement of defective Products to the extent that the defect is 
noticed and Mortara is notified within the warranty period. In no event, including the claim for negligence, 
shall Mortara be liable for incidental, special or consequential damages, or for any other loss, damage or 
expense of any kind, including loss of profits, whether under tort, negligence or strict liability theories of 
law, or otherwise. This warranty is expressly in lieu of any other warranties, expressed or implied, 
including, but not limited to the implied warranty of merchant ability and the warranty of fitness for a 
particular purpose. 

 

Duration and expiration of the Warranty 

 

The Surveyor Central 3.x System carries a 90 day On-Site warranty and a 1 year Depot Repair warranty 
from the date of shipment from Mortara Instrument, Inc. 

 

Warranty Tracking by Serial Number 

 

Mortara Instrument tracks products by serial number for the purposes of warranty, configuration, and 
software version as related to repair, warranty expiration, etc. The serial number will be required for all 
warranty claims made to Mortara Instrument, Inc. 

Summary of Contents for Surveyor Central 3.x

Page 1: ...9516 169 80 ENG Rev B Surveyor Central SERVICE MANUAL Manufactured by Mortara Instrument Inc Milwaukee Wisconsin U S A CAUTION Federal law restricts this device to sale by or on the order of a physic...

Page 2: ...roduced used or disclosed outside of the receiving organization without the express written consent of Mortara Instrument Inc Mortara is a registered trademark of Mortara Instrument Inc E Scribe ELI a...

Page 3: ...t Same Day Shipment of Replacement Parts Biomedical Training Classes Extended Warranties Service Contracts Sales Support Supplies Accessories Mortara Instrument Inc 7865 North 86th Street Milwaukee WI...

Page 4: ...iii...

Page 5: ...inal accessories and supplies that are in compliance with the standard specifications described in this manual The electrical installation of the relevant room complies with the requirements of approp...

Page 6: ...ution Means there is the possibility of damage to the equipment Note Provides information to further assist in the use of the device Refer to Operating Instructions Electrostatic sensitive devices Do...

Page 7: ...ARNINGS Before attempting to use the device for clinical applications the operator must read and understand the contents of the user manual and any documents accompanying the device The Surveyor Centr...

Page 8: ...s and also remove dust regularly from the inside of the device The last operation must be performed by adequately trained and authorized personnel and with the device turned off Install the computer t...

Page 9: ...accessories supplied with the device and available through Mortara Instrument Inc The device captures and presents data reflecting a patient s physiological condition that when reviewed by a trained...

Page 10: ...hat visual representation of an alarm condition remains present after an operator silenced action until the alarm condition disappears unless obscured by another higher priority alarm The auditory ala...

Page 11: ...elemetry Transmitters with frequencies between 904 76 MHz and 925 15 MHz may generate interference In case of interference please try with a different transmission channel refer to the X12 T12 or T12S...

Page 12: ...cable bends protect cables on the floor from wheels of carts cabinets and any pinching or floor traffic Sterilizing this Product Do not sterilize this product or any accessories unless specifically d...

Page 13: ...re used according to manufacturer instructions and that maintenance is performed according to specifications included in this manual Product lifetime starts from the date of manufacture Use of devices...

Page 14: ...Product by its acceptance and purchase thereof acknowledges and agrees that Mortara is not liable for loss harm or damage due directly or indirectly to an occurrence or consequence there from relating...

Page 15: ...Overview This section provides a block diagram of the Surveyor Central system identification of system components and Mortara part number information Note The Telemetry Nodes are computers that contai...

Page 16: ...Surveyor Central 2 2 Note The Telemetry Nodes are computers that contain the PCI RF Boards...

Page 17: ...Multi Parameter Bedside Monitors Data from these systems are transferred to the Surveyor Central 4 X system via a network TCP IP connection The system s shown in the block diagrams are example of a Su...

Page 18: ...workstation through the LNA 611 as shown below DC Power A 2 4 GHz antenna network is connected to the central receiving workstation through the interface DC 2500 as shown below DC Power A 915 MHz ante...

Page 19: ...039 21 Hard Drive SAS 450GB 9906 039 31 USB Watchdog Assembly 30012 017 50 Watchdog Power Supply 4101 007 Standalone Central With Storage Description MORTARA ITEM NUMBER Workstation PC 9906 038 01 Har...

Page 20: ...0 ft 6400 008 Plenum Antenna Ceiling Enclosure 8480 026 Ethernet Networking Description MORTARA ITEM NUMBER 8 PORT SWITCH 4140 012 01 VPN Router WatchGuard 9963 006 04 Network Printer 9007 016 CAT5 Et...

Page 21: ...4 2422 72 74 2438 08 A4 2453 44 D4 2468 8 15 2407 68 45 2423 04 75 2438 4 A5 2453 76 D5 2469 12 16 2408 46 2423 36 76 2438 72 A6 2454 08 D6 2469 44 17 2408 32 47 2423 68 77 2439 04 A7 2454 4 D7 2469 7...

Page 22: ...C 0D Txx 4D T20 8D T36 CD T04 0E 4E 8E CE 0F 4F 8F CF 10 50 90 D0 11 Txx 51 T21 91 T37 D1 T05 12 52 92 D2 13 53 93 D3 14 54 94 D4 15 Txx 55 T22 95 T38 D5 T06 16 56 96 D6 17 57 97 D7 18 58 98 D8 19 Txx...

Page 23: ...37 77 B7 F7 38 78 B8 F8 39 Txx 79 T31 B9 T47 F9 T15 3A 7A BA FA 3B 7B BB FB 3C 7C BC FC 3D Txx 7D T32 BD T48 FD T16 3E 7E BE FE 3F 7F BF FF The above chart shows the transmitters assignments within th...

Page 24: ...615 28 8A 621 28 CA 627 28 4B 615 36 8B 621 36 CB 627 36 4C 615 44 8C 621 44 CC 627 44 4D 615 52 8D 621 52 CD 627 52 4E 615 6 8E 621 6 CE 627 6 4F 615 68 8F 621 68 CF 627 68 50 615 76 90 621 76 D0 62...

Page 25: ...17 24 DC 922 36 1D 907 08 5D 912 2 9D 917 32 DD 922 44 1E 907 16 5E 912 28 9E 917 4 DE 922 52 1F 907 24 5F 912 36 9F 917 48 DF 922 6 20 907 32 60 912 44 A0 917 56 E0 922 68 21 907 4 61 912 52 A1 917 6...

Page 26: ......

Page 27: ...only Prior to performing preventive maintenance be sure the Surveyor Central system is not in active use and all of the clinical data on the system has been properly stored archived Recommended Suppli...

Page 28: ...toring session on the Surveyor Central using the test transmitter and patient simulator Once the system has had enough time to perform and display measurements on the system display select 12 Lead Exp...

Page 29: ...s set to ON for the admitted patient by selecting Alarm Settings then Technical Alarms If the ECG Leads Off setting is set to OFF temporarily change the setting to ON to perform this test Disconnect a...

Page 30: ...ating PC power supply fans Mortara recommends replacing the entire power supply unit Maximizing the Airflow Keep the system server s and the workstation s in an area where the airflow to the front and...

Page 31: ...ending on the system configuration In the case of the Down Converter the light will indicate the selected band which the Telemetry Central 3 X is set to receive If these lights are not illuminated it...

Page 32: ...ate the signal strength area under the Heart Rate Ant A Value Ant B Value dB Refer to the original covered area map to determine which areas of the facility should display acceptable levels of signal...

Page 33: ...onnect it to one transmitter at a time from location 1 defined in the previous tests Start a monitoring session on the monitoring slot that matches the channel of the transmitter being tested and veri...

Page 34: ...tion Check if N A UPS Testing UPS BatteryVerification Replaced Date or Not yet Required check System PC s Inspection Cleaning Antenna Network Maintenance Coax Cable Check Antenna Network Box Check LNA...

Page 35: ...ction troubleshoot printer i e does printer print test page If the printer is able to print a test page verify the printer has the correct IP address assigned to the printer The IP address is accessed...

Page 36: ...disabled Note When alarms are disabled no alarms will sound this includes the arrest alarm be careful when choosing to disable alarms The customer assumes all risks for turning off alarms Rapid beepi...

Page 37: ...Square waves on display for 1 patient only Possible solutions 1 Make sure transmitter is turned on and tuned to the correct channel number 2 Check received signal strength on this channel If received...

Page 38: ...solutions Possible problem with a specific antenna network unit Check unit has both LED s illuminated This symptom can be caused by several failures If the area is related to the antenna which is fart...

Page 39: ...CAT 5 connector has oxidized and requires cleaning The LINK LED at the switch is illuminated when there is another device attached via a CAT 5 cable 1 Make sure the CAT 5 cable connections are clean...

Page 40: ...owing order Storage Node SCS1 then the Telemetry Nodes SCT1 SCT2 and finally the Control Nodes SCV1 SCV2 Note Powering off and on of the Surveyor Telemetry Central system has to be done in the exact o...

Page 41: ...ed 1 0 status RUNNING 13 Jan 7 08 23 24 483 192 168 10 111 SCV1T1 1332 timeman exe 1900 M medapp cpp 985 MedicalApplication set_running Bed 1 0 status RUNNING 13 Jan 7 08 23 24 514 192 168 10 111 SCV1...

Page 42: ...ard and the second 8 telemetry beds will be on the second to bottom board in the Central Station PC To replace the board 1 Locate the Central Station PC that has the offending PCI RF board 2 Shut this...

Page 43: ...ponents 9 Replace the cover to the Central Station PC 10 Reconnect all cables to the Central Station PC Be sure to connect the cables in the same locations as noted in steps 3 and 4 11 Power the syste...

Page 44: ...a command prompt and pinging each node s IP Address per the system network diagram Export and Archive Function Equipment needed X12 T12 S transmitter patient cable patient simulator Start a monitorin...

Page 45: ...g is not in progress Remove the mains plug from the UPS the Central Station must continue to function for 5 minutes without losing power If the system can not be powered by the UPS for a period of 5 m...

Page 46: ...testing re connect the power supply to the antenna network Continue this process for all power supplies in the antenna network When completed testing all of the power supplies remove the spare power...

Page 47: ...rtion or drop out with the transmitter placed at location 1 from the previous test Transmitter s Turn on the ECG simulator and connect it to one transmitter at a time from location 1 defined in the pr...

Page 48: ...ication Pass Fail NA Replaced Date or Not yet Required check Antenna Network Pass Fail NA Coax Cable s Antenna Network Box s LNA Down Converter Antenna Network Power Supply s Pass Fail NA Antenna Netw...

Page 49: ...o EU directives 93 42 Medical Device and 99 5 Radio and Telecommunications Terminal Equipment 2500 MHz network Complies with IEC 60950 IEC 60601 1 1 and IEC 60601 1 2 Complies with ETS 300 440 ETS 301...

Page 50: ...0 100 SpO2 ERMS 2 2 SpO2 PulseRate Accuracy 45 210 BPM ERMS 2 SpO2 Measurement wavelength Red 660nm at 3 5 to 4 5 mW nominal Infrared 905nm at 3 5 to 4 5 mW nominal Verified by clinical tests where me...

Page 51: ...d Protocol aborted Medium low or information only On or Off user selectable Step change Phase change user selectable texts ALARMS OFF Information only with audible reminder user selectable Storage Per...

Page 52: ...6 7 inches Mouse 13 x 6 4 x 3 8 cm 5 x 2 5 x 1 5 inches Weight Central Workstation 16 Kg 35 lbs Redundant Network Server 27 24 Kg 60 lbs Monitor 3 Kg 6 5 lbs Printer 20 4 Kg 45 lbs Keyboard 1 Kg 2 2 l...

Page 53: ...oad Number of outlets needed 2 or 3 per workstation depending on system configuration Voltage 100 240 V In rush current 3 ms Redundant RAID1 0 Server 70A 230V 35A 115V Redundant RAID Server Environmen...

Page 54: ...s Microwave LMR400 attenuation 10dB 45 meters 2 45 GHz Plenum Rated Coaxial Cable for 2500 MHz networks Times Microwave LMR 195 LLPL attenuation 10dB 15 meters Power requirements One power supply ever...

Page 55: ...2 V DC max 500 mA Connector D 5 5mm central pin positive 13 5 cm x 13 5 cm x 5 cm 5 3 x 5 3 x 2 325 grams 11 5 oz Cable Plenum Rated Coaxial Cable for 608 MHz networks BELDEN 82907 attenuation 8 dB 20...

Page 56: ...n Next 3 Under Description click on Initial Recovery Point and then click on Next 4 In the Smart PC Recovery screen select the option Recover PC without preserving new and updated files and then click...

Reviews: