MSD Servo Drive DC-AC Operation Manual
30
Id.-No.: CA97554-001 Date: 06/2012
Des.
Term.
Specification
Isolation
Digital outputs
REL
REL
ISDSH
ISD06
ISD05
ISD04
ISD03
ISD02
ISD01
ISD00
+24V
DGND
RSH
RSH
ENPO
OSD02
OSD01
OSD00
ISA1-
ISA1+
ISA0-
ISA0+
+24V
DGND
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
X4
OSD00
OSD01
OSD02
X4/7
X4/8
X4/9
•
No destruction in case of short-circuit (+24 V ->
GND), but device may briefly shut down
•
I
MAX
= 50 mA, PLC-compatible
•
Terminal scan cycle = 1ms
•
High-side driver
yes
STO (Safe Torque Off)
ISDSH
(STO)
X4/22
•
"Request input" = Low-level
•
OSSD-capable (from hardware version 2)
•
Switching level Low/High: ≤4.8 V / ≥18 V
•
U
IN max
= +24 V DC +20%
•
I
IN
at +24 V DC = typ. 3 mA
yes
RSH
RSH
X4/11
X4/12
Diagnosis STO, both tripping chan-
nels active, one NO contact with au-
tomatically resetting circuit-breaker
(polyswitch)
•
25 V / 200 mA AC, cos
ϕ
= 1
•
30 V / 200 mA DC, cos
ϕ
= 1
X4/12
X4/11
yes
Relay outputs
REL
X4/23
X4/24
Relay, 1 NO contact
•
25 V / 1.0 A AC, cos
ϕ
= 1
•
30 V / 1.0 A DC, cos
ϕ
= 1
•
Switching delay approx. 10 ms
•
Cycle time 1 ms
X4/23
X4/24
Auxiliary voltage
+24 V
X4/2
X4/14
•
Auxiliary voltage to feed the digital control inputs
•
U
H
= U
V
-∆U (∆U typically approx. 1.2 V), no de-
struction in case of shot-circuit (+24 V -> GND),
but device may briefly shut down.
•
I
MAX
= 80 mA (per pin) with self-resetting circuit-
breaker (polyswitch)
yes
Digital ground
DGND
X4/1
X4/13
Reference ground for +24 V, I
MAX
= 80 mA (per pin),
Hardware versions 0..1 with self-resetting circuit-
breaker (polyswitch)
yes
Table 3.4 Specification of control connections X4
ATTENTION!
With high currents flowing through the ground terminals a high
resistance isolation from the device ground is required. This may cause incor-
rect response of the drive (avoid ring currents in the wiring).
NOTE:
Note that in the event of a fault the supply unit may no longer be able
to feed regenerative power from the DC-AC servo drives back into the grid.
In order to prevent destruction of the supply unit braking resistor in sustained
regenerative mode, the DC-AC servo drives and power supply unit can be
mutually locked via X4. For more information and an example of circuit con-
figuration refer to appendix on page 83.
3.7.2 Brake driver
Connector X13 (Size 1 to Size 4) is intended for connection of a motor brake.
Des.
Term.
Specification
Connection
+24 V
BR+
BR-
GND
X13/1
X13/2
X13/3
X13/4
•
Short-circuit-proof
•
Voltage supply is via the control supply
U
V
on X9 or X10
•
U
BR
= U
V
-∆U` (∆U` typically ap-
prox. 1.4 V)
•
To actuate a motor holding brake up
to I
BR
= 2.0 A max., for brakes with
higher current requirements a relay
must be interposed.
•
Overcurrent causes shutdown
•
Also usable as configurable digital
output.
•
Interruptible cable break monitoring
<500 mA in condition "1" (up to relay)
M
Brake (+)
Brake (-)
X13
1
BR+ 2
BR- 3
4
Table 3.5 Specification of terminal connections X13
!