3.13.2 Ready made-up motor cable
CO8336
-
xxx
yyy
1)
Ready made-up motor cable
Configuration option
Cable length (m)
1) yyy stands for length in meters; standard length: 1 m, 5 m, 10 m, 15 m, 20 m, 50 m. Further length on request
Motor cable CO8336-xxx-yyy
Order code
Technical data motor cable
Technical data
C08336-xxx-yyy
1),2)
CB05708-xxx-yyy
1),2)
Continous rated current
10 A
TBD
Surge current
30 A (90s at +72.7 °C)
(+162.9 °F)
TBD
Minimum bend radius
In fixed installation: 60 mm
In flexible use: 120 mm
TBD
Cable diameter range
9 to 14.4 mm
TBD
Cable cross-section
4 x 1.5 mm² +
2 x 1 mm²
4 x 4 mm² +
2 x 1.5 mm²
Temperature range
-50 °C to +90 °C
(-58 °F to +194 °F)
TBD
Wiring
Connector pin / Wiring
2 / U
4 / VV
1 / WWW
PE / yellow; green
5 / Brake +; white
6 / Brake -; black
Connector housing / Screen
Connector type
Size 1
2)
xxx-001 for standard configuration option, others on request
Table 3.12 Technical data motor cable (Connector type Size 1)
Technical data
C08733-xxx-yyy
1),2)
B47916-xxx-yyy
1),2)
CA98676-yyy
1),2)
Continous rated current
44 A
61 A
82 A
Surge current
TBD
Minimum bend radius
In fixed installation: 60 mm
In flexible use: 120 mm
TBD
Cable diameter range
16.2 ±3 mm
TBD
Cable cross-section
4 x 6 mm² +
2 x 1 mm²
4 x 10 mm² +
2 x 1.5 mm²
4 x 16 mm² +
2 x 1.5 mm²
Temperature range
-50 °C to +90 °C
(-58 °F to +194 °F)
TBD
Wiring
Connector pin / Wiring
U / U
V / VV
W / WWW
PE / yellow; green
+ / Brake +; white
- / Brake -; black
Connector housing / Screen
Connector type
Size 1.5
2)
xxx-001 for standard configuration option, others on request
Table 3.13 Technical data motor cable (Connector type Size 1.5)
3.13.3 Switching in the motor cable
ATTENTION!
Switching in the motor cable must take place with the power
cut and the power stage disabled, as otherwise problems such as burned-
off contactor contacts may occur. In order to ensure unpowered switch-on,
you must make sure that the contacts of the motor contactor are closed
before the servo drive power stage is enabled. At the moment the contactor
is switched off it is necessary for the contact to remain closed until the servo
drive power stage is shut down and the motor current is 0. This is done by
inserting appropriate safety times for switching of the motor contactor in the
control sequence of your machine.
Despite these measures, the possibility cannot be ruled out that the servo drive may
malfunction during switching in the motor cable.
!