69
Id.-No.: CA97554-001 Date: 06/2012
B Technical data
B.1 Current capacity of MSD Servo Drive DC-AC
The maximum permissible servo drive output current and the peak current are dependent
on the DC supply voltage, the motor cable length, the power stage switching frequency, the
design of the cooling system and the ambient temperature. If the conditions change, the maxi-
mum permissible current capacity of the servo drives also changes.
B.1.1 Size 1 to Size 4 (air-cooled, 400 V AC)
Type
Po
w
er s
ta
g
e
sw
itc
hi
n
g
fr
eq
u
en
cy
A
m
b
ie
n
t
te
m
p
er
at
ur
e
R
ate
d
cur
re
n
t
Peak current
1)
I
MAX
0 Hz
I
1MAX
≥5 Hz
t
1
2)
I
2MAX
≥5 Hz
t
2
2)
[kHz]
[°C]/[°F]
[A
eff
]
[A
eff
]
[A
eff
]
[s]
[A
eff
]
[s]
G393-004
(Size 1)
4
+40/+104
5.3
8.4
8.4
10
11.9
0.5
8
4.0
8.4
8.4
-
-
12
3.7
6.6
6.6
-
-
16
2.7
5.2
5.2
-
-
G393-006
(Size 1)
4
+40/+104
8.0
12.7
12.7
10
18.0
0.5
8
6.0
12.7
12.7
-
-
12
5.5
9.9
9.9
-
-
16
4.0
7.7
7.7
-
-
G393-008
(Size 2)
4
+40/+104
9.3
15.9
15.9
10
23.9
0.5
8
9.3
15.9
15.9
-
-
12
6.7
9.4
9.4
-
-
16
5.5
7.7
7.7
-
-
1) At max. 70 % preload
2) Shutdown as per I²t characteristic
All data apply for motor cable length ≤10 m
Table B.1 Rated and peak current, Size 1 to Size 4 (air-cooled, 400 V AC)
Type
Po
w
er s
ta
g
e
sw
itc
hi
n
g
fr
eq
u
en
cy
A
m
b
ie
n
t
te
m
p
er
at
ur
e
R
ate
d
cur
re
n
t
Peak current
1)
I
MAX
0 Hz
I
1MAX
≥5 Hz
t
1
2)
I
2MAX
≥5 Hz
t
2
2)
[kHz]
[°C]/[°F]
[A
eff
]
[A
eff
]
[A
eff
]
[s]
[A
eff
]
[s]
G393-012
(Size 2)
4
+40/+104
14.0
24.0
24.0
10
36.0
0.5
8
14.0
24.0
24.0
-
-
12
10.0
14.1
14.1
-
-
16
8.2
11.5
11.5
-
-
G393-016
(Size 3)
4
+40/+104
20.0
33.6
33.6
10
48.0
0.5
8
16.0
33.6
33.6
-
-
12
11.0
23.6
23.6
-
-
16
8.5
19.4
19.4
-
-
G393-020
(Size 3)
4
+40/+104
25.0
42.0
42.0
10
60.0
0.5
8
20.0
42.0
42.0
-
-
12
13.8
29.6
29.6
-
-
16
10.0
22.8
22.8
-
-
G393-024
(Size 4)
4
+40/+104
30.0
48.0
48.0
10
72.0
0.5
8
24.0
48.0
48.0
-
-
12
15.8
31.6
31.6
-
-
16
11.3
22.6
22.6
-
-
G393-032
(Size 4)
4
+40/+104
40.0
64.0
64.0
10
96.0
0.5
8
32.0
64.0
64.0
-
-
12
21.0
42.0
42.0
-
-
16
15.0
30.0
30.0
-
-
1) At max. 70 % preload
2) Shutdown as per I²t characteristic