B.1.6 Size 3 and Size 4 (liquid-cooled, 400 V AC)
Type
Po
w
er s
ta
g
e
sw
itc
hi
n
g
fr
eq
u
en
cy
A
m
b
ie
nt
te
m
p
er
at
ur
e
R
ate
d
cur
re
n
t
Peak current
1)
I
MAX
0 Hz
I
1MAX
≥5 Hz
t
1
2)
I
2MAX
≥5 Hz
t
2
2)
[kHz]
[°C]/[°F]
[A
eff
]
[A
eff
]
[A
eff
]
[s]
[A
eff
]
[s]
G397-020
(Size 3)
4
+40/+104
20.0
33.6
33.6
10
48.0
0.5
8
20.0
33.6
33.6
-
-
12
17.4
26.4
26.4
-
-
16
12.0
18.2
18.2
-
-
G397-025
(Size 3)
4
+40/+104
25.0
42.0
42.0
10
60.0
0.5
8
25.0
42.0
42.0
-
-
12
21.8
33.1
33.1
-
-
16
15.0
22.8
22.8
-
-
G397-026
(Size 4)
4
+40/+104
30.0
48.0
48.0
10
72.0
0.5
8
26.3
48.1
48.1
-
-
12
22.5
31.5
31.5
-
-
16
16.1
22.5
22.5
-
-
G397-035
(Size 4)
4
+40/+104
40.0
64.0
64.0
10
96.0
0.5
8
35.0
64.0
64.0
-
-
12
30.0
42.0
42.0
-
-
16
21.4
29.9
29.9
-
-
1) At max. 70 % preload
2) Shutdown as per I²t characteristic
All data apply for motor cable length ≤10 m
Table B.6 Rated and peak current, Size 3 and Size 4 (liquid-cooled, 400 V AC)
B.1.7 Size 3 and Size 4 (liquid-cooled, 460 V AC)
Type
Po
w
er s
ta
g
e
sw
itc
hi
n
g
fr
eq
u
en
cy
A
m
b
ie
nt
te
m
p
er
at
ur
e
R
ate
d
cur
re
n
t
Peak current
1)
I
MAX
0 Hz
I
1MAX
≥5 Hz
t
1
2)
I
2MAX
≥5 Hz
t
2
2)
[kHz]
[°C]
[A
eff
]
[A
eff
]
[A
eff
]
[s]
[A
eff
]
[s]
G397-020
(Size 3)
4
+40/+104
20.0
33.6
33.6
10
48.0
0.5
8
17.4
29.2
29.2
-
-
12
12.5
19.0
19.0
-
-
16
9.1
13.8
13.8
-
-
G397-025
(Size 3)
4
+40/+104
25.0
42.0
42.0
10
60.0
0.5
8
21.8
36.6
36.6
-
-
12
15.6
23.7
23.7
-
-
16
11.4
17.3
17.3
-
-
G397-026
(Size 4)
4
+40/+104
26.0
41.6
41.6
10
62.4
0.5
8
23.0
42.0
42.0
-
-
12
17.7
24.8
24.8
-
-
16
12.8
17.9
17.9
-
-
G397-035
(Size 4)
4
+40/+104
33.7
53.9
53.9
10
80.9
0.5
8
30.6
55.9
55.9
-
-
12
23.6
33.0
33.0
-
-
16
17.0
23.8
23.8
-
-
1) At max. 70 % preload
2) Shutdown as per I²t characteristic
All data apply for motor cable length ≤10 m
Table B.7 Rated and peak current, Size 3 and Size 4 (liquid-cooled, 460 V AC)