6.4.
Alarms identification
If the drive is used in fieldbus mode (EtherCat / Can), the error code will be transmitted via an EMERGENCY message (according
to the CANOpen standard) consisting of ErrorCode and ErrorRegister
Fault
index
Error code
Error register
Fault
Fault
1
0x2344
0x04
short_circuit_phase_U_low
IGBT fault phase U lower arm
2
0x2345
0x04
short_circuit_phase_U_hi
IGBT fault phase U upper arm
3
0x2346
0x04
short_circuit_phase_V_low
IGBT fault phase U lower arm
4
0x2347
0x04
short_circuit_phase_V_hi
IGBT fault phase U upper arm
5
0x2348
0x04
short_circuit_phase_W_low
IGBT fault phase W lower arm
6
0x2349
0x04
short_circuit_phase_W_hi
IGBT fault phase W upper arm
7
0x3220
0x04
dc_link_under_voltage
Bus undervoltage
8
0x3210
0x04
dc_link_over_voltage
Bus overvoltage
9
0x4310
0x08
excess_temperature_drive
Excessive drive temperature (IGBT module
protection)
10
0x5114
0x04
safety_stage_low_voltage
STO power circuit not detected (this fault is
detected only in “operation Enable”)
11
0x5530
0x01
eeprom_fault
Error reading EEPROM memory from the
power block or invalid content.
12
0x5540
0x01
sd_memory_fault
External memory card not detected.
13
0x6010
0x01
software_watchdog
Software alarm
14
0x6320
0x01
parameter_initialisation_error
Initialisation error
15
0x6311
0x01
node_identi
�
er_data_memory_
corrupted
Not used
16
0x6312
0x01
user_data_memory_corrupted
Parametric user memory corrupt/not
con
�
gured
17
0x6313
0x01
restore_data_memory_corrupted Not used
18
0x6314
0x01
factory_data_memory_corrupted Constructor parameter memory corrupt/not
con
�
gured
19
0x6315
0x01
calibration_data_memory_
corrupted
Not used
20
0x6316
0x01
diagnosis_data_memory_
corrupted
Not used
21
0x7110
0x01
brake_feedback_fault
Brake status signal inconsistent
22
0x7124
0x08
motor_temperature_warning
Motor temperature warning
23
0x7125
0x08
motor_over_temperature
Motor temperature fault
24
0x7380
0x01
Interface X3 - Missing
transducer con
�
guration
Interface X3 transducer enabled but not
con
�
gured
25
0x7381
0x01
Interface X3 - General fault
Not used
26
0x738D
0x01
Interface X3 - Resolver
synchronisation fault
Resolver signal synchronisation error
(phase)
27
0x738E
0x01
Interface X3 - Resolver signals
fault
Signal resolver level error (amplitude)
28
0x7390
0x01
Interface X2 - Missing
transducer con
�
guration
Interface X2 transducer enabled but not
con
�
gured
29
0x7391
0x01
Interface X2 - General fault
Initialisation error or transducer not
detected
30
0x7392
0x01
Interface X2 - Erroneous value of
sincos signals
Sinusoidal signal amplitude inconsistent
DR2020
MAR2-E-191
78
fi
fi
fi
fi