![Moeller S40-AM-TL Manual Download Page 52](http://html1.mh-extra.com/html/moeller/s40-am-tl/s40-am-tl_manual_1819282052.webp)
Example of basic function
block
49
10/00 AWB27-1301-GB
Secondary stations 1 (PS4-200) and 2 (PS416)
Variable declaration “TCMT3_BT”
VAR_INPUT
fixed_length
: USINT(1..8);
User data length for fixed length frames
tra_dat
: ARRAY[0..7] OF BYTE;
Send data array (data array length)
END_VAR
VAR_OUTPUT
rec_dat
: ARRAY[0..7] OF BYTE;
Receive data array (data array length)
END_VAR
VAR_IN_OUT
TCM_tdata
: ARRAY[1..36] OF BYTE;
Base address for send data
TCM_rdata
: ARRAY[1..36] OF BYTE;
Base address for receive data
END_VAR
VAR CONSTANT
rts_select
: BOOL:= 0;
RTS switched/static-on
time_tout
: TIME:= T#10s;
Protocol monitoring time
rts_delay_on
: TIME:=T#10ms;
RTS on-delay
rts_delay_off : TIME:=T#30ms;
RTS off-delay
cts_gap_time
:TIME:=T#0ms;
CTS timeout gap_time
END_VAR