Installation
31
10/00 AWB27-1301-GB
The parentheses must be set as follows for asynchronous
mode:
Parameters
The parameters must adjusted accordingly depending on the
application of the telecontrol module used. They are set in
the declaration section of the TCMTx_xx parameter function
blocks in the constant block, and are assigned default
values.
The following parameters are only transferred when the
module is cold/warm started or reset:
• rts_delay_off
• cts_gap_time
• cts_time
• rts_select
(*Synchronous mode PS4-201/341 with x_bus_mode=0*)
LD
NKD_1
PLC_message
ST
fb_line.x_NKD_syn
LD
0
ST
fb_line.x_bus_mode
(*Asynchronous mode PS4-341/416 with x_bus_mode=1
LD
1
ST
fb_line.x_NKD_syn
ST
fb_line.x_bus_mode *)
(*Synchronous mode PS4-201/341 with x_bus_mode=0
LD
NKD_1
etc.
ST
fb_line.x_bus_mode *)
(*Asynchronous mode PS4-341/416 with x_bus_mode=1*)
LD
1
ST
fb_line.x_NKD_syn
ST
fb_line.x_bus_mode