![Moeller S40-AM-TL Manual Download Page 37](http://html1.mh-extra.com/html/moeller/s40-am-tl/s40-am-tl_manual_1819282037.webp)
Function Blocks
34
10/00 AWB27-1301-GB
TCMT2_BT
TCMT2_US
VAR CONSTANT
rts_select
: BOOL:= 0;
(*RTS switched/static-on*)
dfn_max
: UINT:= 16;
(*Number of secondary stations*)
tra_dfl_max
: UINT:=20;
(*Transmit length of data array*)
rec_dfl_max
: UINT:=20;
(*Receive length of data array*)
system_time
: TIME:=T#500ms;
(*System time*)
repeat_time
: TIME:=T#50ms;
(*repeat time after job end*)
start_delay
: TIME:=T#2000ms;
(*Start delay with autostart*)
rts_delay_on
: TIME:=T#10ms;
(*RTS on-delay*)
rts_delay_off
: TIME:=T#30ms;
(*RTS off-delay*)
cts_gap_time
:TIME:=T#0ms;
(*CTS timeout gap_time*)
tel_repeat
: USINT:=3;
(*Frame repeated in the event of an
error*)
END_VAR
VAR CONSTANT
dfn_max
: UINT:=32;
(*Number of secondary stations*)
tra_sub_max
: UINT:= 0;
(*Transmit number of subaddresses*)
rec_sub_max
: UINT:= 0;
(*Receive number of subaddresses*)
tra_dfl_max
: UINT:=20;
(*Transmit length of data array*)
rec_dfl_max
: UINT:=20;
(*Receive length of data array*)
system_time
: TIME:=T#500ms;
(*System time*)
repeat_time
: TIME:=T#50ms;
(*repeat time after job end*)
start_delay
: TIME:=T#2000ms;
(*Start delay with autostart*)
rts_delay_on
: TIME:=T#10ms;
(*RTS on-delay*)
rts_delay_off
: TIME:=T#30ms;
(*RTS off-delay*)
cts_time
: TIME:=T#500ms;
(*CTS timeout*)
END_VAR
Summary of Contents for S40-AM-TL
Page 7: ...10 00 AWB27 1301 GB 4 ...
Page 9: ...6 10 00 AWB27 1301 GB ...
Page 13: ...10 10 00 AWB27 1301 GB ...
Page 55: ...Basic Function Blocks 52 10 00 AWB27 1301 GB ...
Page 103: ...100 10 00 AWB27 1301 GB ...
Page 107: ...104 10 00 AWB27 1301 GB ...
Page 113: ...10 00 AWB27 1301 GB 110 ...