9. Maintenance
9-3
(3) Cleaning and Replacement of Filter
IS-120B has filters at its intake and outlet (See the figure below).
Clean the filters once a half year observing the following procedures.
If it gets badly stained, replace it with a new one. If the filter is clogged, air does not
flow enough, causing internal temperature to rise and malfunction.
•
Miyachi Technos Corp. does not have a replacement filter; please purchase it
from manufacturer.
[Manufacturer and Model Number of Replacement Filter]
Manufacturer: NITTO KOGYO CO., LTD.
Model Number: SLP-F1 (10 sheet) for IS-120B intake
SLP-F2 (10 sheet) for IS-120B outlet
•
Cut the replacement filters as shown:
87mm
87
m
m
SLP-F1 for Intake
15mm-45deg at 4 corners
116mm
116m
m
SLP-F2 for Outlet
15mm-45deg at 4 corners
DANGER
!
Fan motor may hurt your finger.
When cleaning or replacing the filter, be sure to turn off
the power supply first.