IS-120B
10. Specifications
10-3
Current monitor
(CURRENT HIGH/
LOW)
[
HIGH
]
range mode
Upper limit (
HIGH
) setting range:
(Monitor is turned off, if set to 00.0kA.)
Lower limit (
LOW
) setting range:
(Monitor is turned off, if set to 00.0kA.)
[
LOW
]
range mode
Upper limit (
HIGH
) setting range:
(Monitor is turned off, if set to 00.0kA.)
Lower limit (
LOW
) setting range:
(Monitor is turned off, if set to 00.0kA.)
00.0kA-20.0kA
15 schedules
00.0kA-20.0kA
15 schedules
0.00kA-9.99kA
15 schedules
0.00kA-9.99kA
15 schedules
Voltage monitor
(VOLT HIGH/LOW)
Upper limit (
HIGH
) setting range:
(Monitor is turned off, if set to 0.00V.)
Lower limit (
LOW
) setting range:
(Monitor is turned off, if set to 0.00V.)
0.00V-9.99V
15 schedules
0.00V-9.99V
15 schedules
Power monitor
(POWER HIGH/LOW)
[
HIGH
]
range mode
Upper limit (
HIGH
) setting range:
(Monitor is turned off, if set to 00.0kW.)
Lower limit (
LOW
) setting range:
(Monitor is turned off, if set to 00.0kW.)
[
LOW
]
range mode
Upper limit (
HIGH
) setting range:
(Monitor is turned off, if set to 00.0kW.)
Lower limit (
LOW
) setting range:
(Monitor is turned off, if set to 00.0kW.)
00.0kW-20.0kW
15 schedules
00.0kW-20.0kW
15 schedules
0.00kW-9.99kW
15 schedules
0.00kW-9.99kW
15 schedules
Pulse width monitor
(PULSE % HIGH)
Setting range: 10% - 100%
Weld count monitor
(WELD COUNT)
Setting range: 00 - 99 times
State indicator LED
①
[WELD POWER] lamp
③
[START] lamp
⑤
[TROUBLE] lamp
②
[READY] lamp
④
[WELD] lamp
⑥
[WELD ON/OFF] lamp
Memory backup
battery
Lithium battery
(Data backup period: 5 years after shipment)
Cooling method
Air-cooled (fan motor)
Operating
environment
①
Ambient temperature :
②
Humidity :
③
Altitude :
④
Pollution degree :
+5 to +40
℃
90% max. (no condensation)
1000m max.
Protection degree IP40
Transportation and
storage conditions
①
Ambient temperature:
②
Humidity:
③
Pollution degree :
-10 to +55
℃
90% max. (no condensation)
Protection degree IP40