IS-120B
3. Name and Functions of Each Section
3-4
(2) Rear Panel
①
Connecting terminal block for external input/output signal
This terminal block is used to input the schedule signals and output trouble
signals.
②
Welding Power Supply Breaker
For three-phase power supply.
③
Welding Power Supply Breaker Lever
Pulling up this Lever supplies power; pushing down, disconnect power supply.
④
Trip Button of Welding Power Supply Breaker
Checks trip operation of the Breaker. Periodic checks are recommended.
⑤
Welding Transformer
[
I/O
]
connector
For connecting
[
SENS
]
cable of welding transformer manufactured by Miyachi
Technos Corp.
⑥
Terminal block for welding power output
This terminal block is used to connect to the input of the welding transformer.
Power supply breaker
cover
PE
L3
L2
L1
U
V
POWER OUT
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
14
13
12
11
10
9
8
7
6
5
4
3
2
1
I/O terminal cover
Output terminal cover
(with terminal cover mounted)
(with terminal covers removed)
①
Rear panel
I / O
②
③
④
⑤
⑥