IS-120B
6. Interface
6-2
Terminal strip specifications
Rated voltage: 125VAC minimum.
Withstand voltage: 1200V minimum.
Pressure wire connectors: M3 or M3.5
(
7.1mm wide
)
Two pieces max. connectable.
Recommended wire size: 0.75mm
2
min. for terminal nos. 1 to 5
0.5mm
2
min. for terminal nos. 6 to 31
*
RY1 - RY3
Model G6B1114P (OMRON)
Coil voltage: 24VDC
Contact capacity: 110VAC 0.5A
(2) External Input/Output Signals
・
Pins 1, 2 :
Terminals to accept power to drive the valve
(
100VAC or 24VDC
)
.
・
Pin 3 :
Common terminal for valve output.
・
Pins 4, 5 :
Squeeze output terminals for valves
(
Input voltage to Pin 1, 2 is
output
)
. 4 = Valve 1, 5 = Valve 2
Do not connect a valve of more than 0.5A. When using a valve of
more than 0.5A, operate an auxiliary relay with this VALVE output
and supply a voltage with the relay contact to the valve.
・
Pin 6 :
0V terminal for
IS-120B
only. Do NOT use for another purpose.
・
Pin 7 :
24V terminal for
IS-120B
only. Do NOT use for another purpose.
・
Pin 8 :
Control power input terminal for external signals. Connect Pin 6
or 7 to this terminal depending on input signal circuit.
・
Pin 9 :
Common terminal for external signals. Connect pin 6 or 7 to this
terminal according to input signal circuit.
・
Pin 10 :
Common terminal for schedule signal input.
・
Pins 11-14 :
Schedule input terminals. Generally used for schedule selection
signal input and start signal input.
11 = Schedule 1, 12 = Schedule 2, 13 = Schedule 4,
14 = Schedule 8
・
Pin 15 :
Common terminal for input.
32
33
34
35
36
37
38
39
*(RY1)
READY
END
*(RY2)
*(RY3)
ERROR
VOLT SENS
(Secondary
voltage input)