IS-120B
4. How to Operate Screens
4-17
(
c
)
RESET MODE
Set the reset method to be applied when any ERROR signal is output
(
when
the current or voltage is out of the conditions set on
(5)MONITOR SET
Screen
)
.
If the ERROR signal is not reset, the next workpiece cannot be welded.
ON
Input
ERROR RESET
signal to reset trouble.
OFF
Input
SCHEDULE
signal or
ERROR RESET
signal to reset trouble.
(
d
)
CYC WELD
Change the unit of
TIME
,
UP SLOPE
and
DOWN SLOPE
set on
(3)SCHEDULE Screen
.
ON
CYC
1 CYC = 20ms at 50Hz
1 CYC = 16.6ms at 60Hz
OFF
ms
(
e
)
STEPPER
Turn on and off the step-up
(
down
)
operation
(
See
(9)STEPPER COUNT
Screen
)
.
ON
Step-up
(
down
)
operation is turned on.
OFF
Step-up
(
down
)
operation is turned off.
(f) CURR. RANGE
Switches the range of
HEAT
that is set
on
SCHEDULE
Screen
.
Range
Current setting
Power setting
HIGH
(
Initial setting
)
Maximum setting 20.0 kA
Minimum setting 00.1 kA
Maximum setting 20.0 kW
Minimum setting 00.1 kW
LOW
Maximum setting 9.99 kA
Minimum setting 0.10 kA
Maximum setting 9.99 kW
Minimum setting 0.10 kW
ATTENTION
In accordance with the Current Ranges, the value of detecting “No Current
Error” differs respectively. That is:
0.8kA or less in
HIGH
Range, 0.08kA or less in
LOW
Range
Therefore, if the current is set to 0.8kA or less in the operation of
HIGH
Range, “No Current Error” is detected.
Beforehand, change to
LOW
Range to perform the operation.
HIGH and LOW ranges do not affect Secondary constant-voltage effective
value control and Constant-phase control.