IS-120B
10. Specifications
10-5
Method
Asynchronous, Simplex
Transmission rate : 9600 bps
Start bit : 1 bit
Data bit : 8 bit (ASCII code)
Parity bit : Even parity
Stop bit : 1 bit
Transmission format
(
1
)
Monitor data in HIGH range mode
Item
Character
train
Description
Range
1 M,
Identifier
M (fixed)
2 nnnn,
Control No.
0000 ~ 9999
3 nn,
Welding schedule No
.
01 ~ 15
4 C or m,
C:CYC m:ms
C or m
5 nnn,
WELD1 time
C: 000 ~ 099
m: 000 ~ 600
6 nn. n,
WELD1 current
00.0 ~ 20.0
7 n. nn,
WELD1 voltage
0.00 ~ 9.99
8 nn. n,
WELD1 power
00.0 ~ 20.0
9 nn. n
WELD1
pulse width
00.0 ~ 99.9
--.-
for primary
constant-current peak
value control
10 nnn,
WELD2 time
C: 000 ~ 099
m: 000 ~ 600
11 nn. n,
WELD2 current
00.0 ~ 20.0
12 n. nn,
WELD2 voltage
0.00 ~ 9.99
13 nn. n,
WELD2 power
00.0 ~ 20.0
14 nn. n,
WELD2
pulse width
00.0 ~ 99.9
--.-
for primary
constant-current peak
value control
15 nnnn,
Valve 1 Stepper count
0000 ~ 9999
16 n,
Valve 1 Step No.
0 ~ 9
17 nnnn,
Valve 2 Stepper count
0000 ~ 9999
18 n,
Valve 2 Step No.
0 ~ 9
19 nn,
Monitor count
00 ~ 99
20
Linefeed code
RS-485
Serial interface
specifications
Example :
M, 0001, 05, C, 020, 05.0, 0.00, 00.0, 20.0, 000,
00.0, 0.00, 00.0, 00.0, 0020, 1, 0000, 0, 00