- 42 -
Problem
Cause Remedy
23. The overload alarm
does not function
properly.
(1) The power supply line is not correctly
connected to the board.
(1) Correctly connect the power
supply line. Connect “1”
and “S” to “A” and “B” on the
board.
24. The pushbutton will
not go down smoothly
or will not smoothly
pop up.
(1) Foreign material caught by inner unit
(2) Defective inner unit
(1) Check or repair.
(2) Replace.
25. Pressing the DOWN
pushbutton lowers the
load, but pressing the
UP pushbutton also
lowers the load.
(1) Rotor slippage (The rotor is not properly
engaged with the motor shaft.)
(1) Replace.
* In this case, releasing the
pushbutton will
immediately stop the
lowering operation.
Summary of Contents for UM 10t
Page 51: ... 47 Structural Drawing of Hoist Main Body 5t 10t PA00531 ...
Page 52: ... 48 Structural Drawing of Electric Traversing Unit Monorail Type 10t P288922 ...
Page 53: ... 49 Structural Drawing of Electric Traversing Unit Double rail type 5t PA00483 ...
Page 54: ... 50 Structural Drawing of Traversing Mortor Double rail type 10t P276926 ...
Page 55: ... 51 Structural Drawing of Hook Block 5t PG49975 ...