33
CHAPTER 3 SPECIFICATIONS
3
3.5 List of Remote I
/O Signals
3.5.1
Main A/D converter module
Do not use any "Use prohibited" remote I/O signals. If any of the signals are used, correct operation of the module cannot be
guaranteed.
Module type
Remote input
Remote output
Signal direction: Main A/D converter module
→
Master/local
module
Signal direction: Master/local module
→
Main A/D converter
module
Device No.
Description
Device No.
Description
Main A/D
converter module
RX0
Use prohibited
RY0
Use prohibited
RX1
Use prohibited
RY1
Use prohibited
RX2
Use prohibited
RY2
Use prohibited
RX3
Use prohibited
RY3
Use prohibited
RX4
Use prohibited
RY4
Use prohibited
RX5
Use prohibited
RY5
Use prohibited
RX6
Use prohibited
RY6
Use prohibited
RX7
Warning flag
RY7
Use prohibited
RX8
Use prohibited
RY8
Use prohibited
RX9
Initial data setting completion flag
RY9
Initial data setting request flag
RXA
Error flag
RYA
Error clear request flag
RXB
Remote READY
RYB
Use prohibited
RXC
Use prohibited
RYC
Use prohibited
RXD
Use prohibited
RYD
Use prohibited
RXE
Use prohibited
RYE
Use prohibited
RXF
Use prohibited
RYF
Use prohibited
RX10
CH1 A/D conversion completed flag
RY10
Use prohibited
RX11
CH2 A/D conversion completed flag
RY11
Use prohibited
RX12
CH3 A/D conversion completed flag
RY12
Use prohibited
RX13
CH4 A/D conversion completed flag
RY13
Use prohibited
RX14
CH1 Difference conversion state flag
RY14
CH1 Difference conversion trigger
RX15
CH2 Difference conversion state flag
RY15
CH2 Difference conversion trigger
RX16
CH3 Difference conversion state flag
RY16
CH3 Difference conversion trigger
RX17
CH4 Difference conversion state flag
RY17
CH4 Difference conversion trigger
RX18
Alert output signal
RY18
Use prohibited
RX19
Trigger conversion completed flag
RY19
Trigger conversion request
RX1A
Use prohibited
RY1A
Trigger conversion completed clear request
RX1B
Use prohibited
RY1B
Use prohibited
RX1C
Input signal error detection signal
RY1C
Use prohibited
RX1D
Maximum value/minimum value reset
completed flag
RY1D
Maximum value/minimum value reset request
RX1E
Use prohibited
RY1E
Use prohibited
RX1F
External power supply monitor status flag (for
extension output module)
RY1F
External power supply monitor request flag
(for extension output module)
Summary of Contents for NZ2EX2B-60AD4
Page 2: ......
Page 49: ...47 CHAPTER 4 PROCEDURES BEFORE OPERATION 4 Memo ...
Page 156: ...154 3 In the dialog box that appears shown below click button ...
Page 169: ...167 CHAPTER 10 MAINTENANCE AND INSPECTION 10 Memo ...
Page 253: ......