90
1 SERVO PARAMETER DETAILS
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
1.7
Extension setting 3 servo parameters group ([Pr.
PF_ _ ])
[Pr. PF02_Function selection F-2 (*FOP2)]
[Pr. PF02.0_Target alarm selection of the other axis error warning]
Select target alarms of the other axis error warning.
For alarms occurring at all axes, [AL. 0EB The other axis error warning] will not occur regardless of alarm No.
[AL. 0EB The other axis error warning] does not occur in 1-axis servo amplifiers.
0: [AL. 024 Main circuit error], [AL. 032 Overcurrent]
1: All alarms
[Pr. PF02.4_Memory writing frequency warning enable/disable selection]
Enable or disable [AL. 1F8.1 Memory writing frequency warning].
[AL. 1F8.1] indicates that the memory writing frequency has exceeded the guaranteed number of times.
If the servo amplifier continues to be used while the alarm is disabled with this servo parameter, the memory may be
corrupted and restoration of the data, such as servo parameters, may fail.
0: Enabled
1: Disabled
[Pr. PF02.5_Memory free space warning enable/disable selection]
Select whether to enable or disable [AL. 1F8.2 Memory free space warning].
[AL. 1F8.2] indicates that the memory free space is running low.
If the servo amplifier continues to be used while the alarm is disabled with this servo parameter, [AL. 119.7 Memory free space
4-1] may occur and data restoration may fail.
0: Enabled
1: Disabled
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Common
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
C4
Initial value
Setting range
Ver.
0h
Refer to the text
C4
Initial value
Setting range
Ver.
0h
Refer to the text
C4