36
3 SIGNALS AND WIRING
3.1 Example power circuit connections
For 3-phase 200 V AC to 240 V AC power supply [WG]
MC
*5
L1
L2
L3
/
P4
P+
L11
L21
D
C
U
V
W
CNP1
CNP3A
*9
CNP2
U
V
W
CN2A
MC
MCCB
MC
SK
M
N-
RA1
*4
*7
U
V
W
CNP3B
*9
U
V
W
CN2B
M
*4
U
V
W
CNP3C
*9
U
V
E
E
E
W
CN2C
M
*4
PE ( )
*1
*2
*2
*2
*10
RA2
AND
malfunction
*3
OFF
ON
Emergency stop switch
Servo amplifier
A-axis servo motor
Power
supply
*6
Motor
Encoder
B-axis servo motor
Motor
Encoder
C-axis servo motor
*8
Motor
Encoder
Servo motor
overheat
protection
*11