3 SIGNALS AND WIRING
3.6 Interface
95
3
■
Open-collector type
• Interface
*1 A photocoupler is used as the pulse train input interface. Therefore this circuit may not operate properly due to reduction in current if a
resistor is connected to the pulse train signal line.
• Input pulse condition
Encoder output pulse DO-2
■
Differential line driver type
• Interface
Maximum output current: 35 mA
• Output pulse
OPC
SD
DOCOM
*1
PP, NP
Servo amplifier
Max. input pulse
frequency 200 kpulses/s
24 V DC
Approx. 1.2 k
Ω
2 m or less
0.9
0.1
tc
tLH
tc
tHL
tF
PP
NP
tLH = tHL < 0.2
μ
s
tc > 2
μ
s
tF > 3
μ
s
150
Ω
LA
(LB, LZ)
LAR
(LBR, LZR)
SD
LG
100
Ω
LAR
(LBR, LZR)
SD
LA
(LB, LZ)
Servo amplifier
Servo amplifier
Am26LS32 or
equivalent
High-speed
photocoupler
T
LA
LAR
LB
LBR
LZ
LZR
π
/2
Servo motor CCW rotation
400
μ
s or more