4 - 2
4. DISPLAY SECTION AND OPERATION SECTION OF THE CONVERTER UNIT
4.2 Status display mode
The servo status during operation is shown on the 4-digit, 7-segment LED display. Press the "UP" or
"DOWN" button to change display data as desired.
When the required data is selected, the corresponding symbol is displayed. Press the "SET" button to
display that data.
The converter unit display section can show four items of data such as the effective load factor.
4.2.1 Display examples
The following table shows the display examples.
Item
Status
Display
Bus voltage
225[V]
Effective load factor
67[%]
Peak load factor
95[%]
Regenerative load factor
90[%]
4.2.2 Status display list
The following table lists the servo statuses that may be displayed.
Status Display
Symbol
Unit
Description
Indication Range
Bus voltage
d
V
The converter unit voltage is displayed.
150 to 500
Effective load factor
J
%
Continuous effective load torque is displayed. (Note)
The effective value is displayed relative to the rated
torque of 100%.
0 to 300
Peak load factor
b
%
The peak output is displayed. (Note)
The peak value in the past 15 seconds is displayed
relative to the rated torque of 100%.
0 to 300
Regenerative load
factor
L
%
The percentage of regnerative power to the
permissible regenerative value is displaed.
0 to 300
Note: Output speed torque
Summary of Contents for Melservo-H Series
Page 11: ... 4 MEMO ...
Page 23: ...1 12 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 41: ...3 16 3 SIGNALS AND WIRING MEMO ...
Page 49: ...4 8 4 DISPLAY SECTION AND OPERATION SECTION OF THE CONVERTER UNIT MEMO ...
Page 61: ...7 6 7 OUTLINE DIMENSIONAL DRAWINGS MEMO ...
Page 81: ...9 16 9 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...
Page 91: ...App 10 APPENDIX MEMO ...