3 - 15
3. SIGNALS AND WIRING
3.4 Grounding
WARNING
•
Gorund the servo amplifier and servo motor securely
The servo amplifier switches the power transistor on-off to supply power to the servo motor. Depending on
the wiring and ground cablerouting, the servo amplifier may be affected by the switching noise (due to
di/dt and dv/dt) of the transistor. To prevent such a fault, refer to the following diagram and always
ground.
Control box
Servo amplifier
L
11
L
21
P
N
Li
ne f
ilt
er
NFB
MC
Earth plate
CN2
U
V
W
Outer
box
Servo motor
Encoder
SM
U
V
W
3-phase
200 to
230VAC
Must be grounded
by cable
L
2
L
3
L
1
L
21
L
11
Converter
unit
P
N
Pro
g
ramma
ble
cont
roll
er
Summary of Contents for Melservo-H Series
Page 11: ... 4 MEMO ...
Page 23: ...1 12 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 41: ...3 16 3 SIGNALS AND WIRING MEMO ...
Page 49: ...4 8 4 DISPLAY SECTION AND OPERATION SECTION OF THE CONVERTER UNIT MEMO ...
Page 61: ...7 6 7 OUTLINE DIMENSIONAL DRAWINGS MEMO ...
Page 81: ...9 16 9 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...