4. Additional instructions
The following instructions should also be fully noted. Incorrect handling may cause a fault, injury, electric
shock, etc.
(1) Transportation and installation
CAUTION
•
Transport the products correctly according to their weights.
•
Stacking in excess of the specified number of products is not allowed.
•
Do not climb or stand on servo equipment. Do not put heavy objects on equipment.
•
The Converter unit must be installed in the specified direction.
•
Leave specified clearances between the Converter unit and control enclosure walls or other equipment.
•
Do not install or operate the Converter unit which has been damaged or has any parts missing.
•
Provide adequate protection to prevent screws and other conductive matter, oil and other combustible
matter from entering the Converter unit.
•
Do not drop or strike converter unit or servo motor. Isolate from all impact loads.
•
Use the servo amplifier and servo motor under the following environmental conditions:
Conditions
Environment
Servo amplifier
[°C]
0 to 55 (non-freezing)
Ambient
temperature
[°F]
32 to 131 (non-freezing)
Ambient humidity
90%RH or less (non-condensing)
[°C]
20 to 65 (non-freezing)
Storage
temperature
[°F]
4 to 149 (non-freezing)
Storage humidity
90%RH or less (non-condensing)
Ambience
Indoors (no direct sunlight) Free from corrosive gas, flammable gas, oil mist, dust and
dirt
Altitude
Max. 1000m (3280 ft) above sea level
[m/s
2
]
5.9 or less
Vibration
[ft/s
2
]
19.4 or less
•
When the equipment has been stored for an extended period of time, consult Mitsubishi.
Summary of Contents for Melservo-H Series
Page 11: ... 4 MEMO ...
Page 23: ...1 12 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 41: ...3 16 3 SIGNALS AND WIRING MEMO ...
Page 49: ...4 8 4 DISPLAY SECTION AND OPERATION SECTION OF THE CONVERTER UNIT MEMO ...
Page 61: ...7 6 7 OUTLINE DIMENSIONAL DRAWINGS MEMO ...
Page 81: ...9 16 9 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...
Page 91: ...App 10 APPENDIX MEMO ...