PARAMETERS
131
No.
Item
Instruction
Code
Description
Number of
Data Digits
(Data code
FF=1)
9
Parameter write
H80 to
HFD
10 Parameter read
H00 to
H7B
Refer to the "Data Code List" (page 192) and
write and/or read the values as required.
4 digits
Read
H7F
11
Link
parameter
expansion
setting
Write
HFF
H00 to H6C and H80 to HEC parameter values
are changed.
H00: Pr. 0 to Pr. 96 values are accessible.
H01: Pr. 117 to Pr. 158 and Pr. 901 to Pr. 905
values are accessible.
H02: Pr. 160 to Pr. 192 and Pr. 232 to Pr. 254
values are accessible.
H03: Pr. 338 to Pr. 340 values are accessible.
(When "100, 101, 110 or 111" is set in
Pr. 119 or when the communication
option is fitted), Pr. 342 value is
accessible, Pr. 345 to Pr. 348 values are
accessible (fitted with FR-E5ND).
H05: Pr. 500 to Pr. 502 values are accessible.
(fitted with communication option)
H09: Pr. 990 and Pr. 991 values are
accessible.
2 digits
Read
H6C
12
Second
parameter
changing
(Code
HFF=1)
Write
HEC
When setting the bias/gain (data codes H5E to
H61, HDE to HE1) parameters
H00: Offset/gain
H01: Analog
H02: Analog value of terminal
2 digits
REMARKS
For the instruction codes HFF, HEC, their set values are held once they are written,
but changed to 0 when the inverter is reset or all clear is performed.