![Mitsubishi Electric FR-E 520S EC Instruction Manual Download Page 62](http://html.mh-extra.com/html/mitsubishi-electric/fr-e-520s-ec/fr-e-520s-ec_instruction-manual_239223062.webp)
48
(5) Communication operation mode
(Pr. 79 "operation mode selection" = 0 or 1)
Communication operation can be performed by connecting a personal computer and
the PU connector with the RS-485 communication cable.
The inverter setup software is available as an FR-E500 inverter start-up support
software package.
Preparation
!
Connection cable ........................ Connector: RJ45 connector
Cable: Cable conforming to EIA568
(e.g. 10BASE-T cable)
!
Personal computer
!
RS-485, RS-232C converter ....... To be prepared when the communication port of
the personal computer has RS-232C
specifications.
3.1.2 Power on
Before switching power on, check the following.
"
"
"
"
Installation check
Make sure that the inverter is installed correctly in a proper location. (Refer to page
11.)
!
Wiring check
Make sure that the main and control circuits are wired correctly.
Make sure that the options and peripheral devices are selected and connected
correctly. (Refer to page 13.)
"
"
"
"
Switch power on
Power-on is complete if the POWER lamp is lit and the ALARM lamp is off.