![Mitsubishi Electric FR-E 520S EC Instruction Manual Download Page 33](http://html.mh-extra.com/html/mitsubishi-electric/fr-e-520s-ec/fr-e-520s-ec_instruction-manual_239223033.webp)
INSTALLATION AND WIRING
20
2) FR-E520S-0.4K to 2.2K-EC
Cables
PVC Insulated
Cables
Crimping
Terminals
mm
2
AWG
mm
2
Applicable
Inverter
Type
Terminal
Screw
Size
Tight-
ening
Torque
N
⋅⋅⋅⋅
m
L
1
, N
U, V, W
L
1
, N
U, V, W
L
1
, N
U, V, W
L
1
, N
U, V, W
FR-E520S-
0.4K-EC
M4
1.5
2-3.5
2-3.5
2
2
14
14
2.5
2.5
FR-E520S-
0.75K-EC
M4
1.5
2-4
2-4
2
2
14
14
2.5
2.5
FR-E520S-
1.5K-EC
M4
1.5
2-4
2-4
2
2
14
14
2.5
2.5
FR-E520S-
2.2K-EC
M4
1.5
5.5-4
2-4
3.5
2
12
14
4
2.5
Note: 1. The cables used should be 75
°
C copper cables.
2. Tighten the terminal screws to the specified torques.
Undertightening can cause a short or misoperation.
Overtightening can cause the screws and unit to be damaged, resulting in a
short or misoperation.
2