PARAMETERS
66
4.1.2 List of Parameters Classified by Purpose of Use
Set the parameters according to the operating conditions. The following list indicates
purpose of use and corresponding parameters.
Parameter Numbers
Purpose of Use
Parameter numbers which must be set
Operation mode selection
Pr. 79
Acceleration/deceleration
time/pattern adjustment
Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 29
Selection of output characteristics
optimum for load characteristics
Pr. 3, Pr. 14, Pr. 19
Output frequency restriction (limit)
Pr. 1, Pr.2, Pr.18
Operation over 50Hz
Pr. 1, Pr. 18, Pr. 38, Pr. 39, Pr. 903, Pr. 905
Adjustment of frequency setting
signals and outputs
Pr. 38, Pr. 39, Pr. 73, Pr. 254, Pr. 902 to Pr. 905
Motor output torque adjustment
Pr. 0, Pr. 80
Brake operation adjustment
Pr. 10, Pr. 11, Pr. 12
Multi-speed operation
Pr. 1, Pr. 2, Pr. 4, Pr. 5, Pr. 6, Pr. 15, Pr. 24,
Pr. 25, Pr. 26, Pr. 27, Pr. 232, Pr. 233, Pr. 234,
Pr. 235, Pr. 236, Pr. 237, Pr. 238, Pr. 239
Jog operation
Pr. 15, Pr. 16
Frequency jump operation
Pr. 31, Pr. 32, Pr. 33, Pr. 34, Pr. 35, Pr. 36
Automatic restart operation after
instantaneous power failure
Pr. 57, Pr. 58
Optimum acceleration/deceleration
within continuous rated range
Pr. 60
Slip compensation setting
Pr. 245 to Pr. 247
Relat
ed t
o
operat
ion
Output stop method selection
Pr. 250
General-purpose magnetic flux
vector control operation
Pr. 80
Electromagnetic brake operation
timing
Pr. 42, Pr. 190 to Pr. 192
Offline auto tuning setting
Pr. 82 to Pr. 84, Pr. 90, Pr. 96
Sub-motor operation
Pr. 0, Pr. 3, Pr. 7, Pr. 8, Pr. 9, Pr. 44, Pr. 45,
Pr. 46, Pr. 47, Pr. 48
Regenerative function selection
Pr. 30, Pr. 70
Operation in communication with
personal computer
Pr. 117 to Pr. 124, Pr. 338 to Pr. 340, Pr. 342
Operation under PID control
Pr. 73, Pr. 79, Pr. 128 to Pr. 134,
Pr. 180 to Pr. 183, Pr. 190 to Pr. 192
Relat
ed t
o
applicat
ion
operat
ion
Noise reduction
Pr. 72, Pr. 240