PARAMETERS
61
Func-
tion
Para-
meter
Number
Name
Setting
Range
Minimum
Setting
Increments
Factory
Setting
Refer
To:
Custo-
mer
Setting
27
Multi-speed setting (speed 7)
0 to 400Hz,
9999
0.01Hz
(Note 3)
9999
72
29
Acceleration/deceleration
pattern
0, 1, 2
1
0
82
30
Regenerative function
selection
0, 1
1
0
83
31
Frequency jump 1A
0 to 400Hz,
9999
0.01Hz
(Note 3)
9999
84
32
Frequency jump 1B
0 to 400Hz,
9999
0.01Hz
(Note 3)
9999
84
33
Frequency jump 2A
0 to 400Hz,
9999
0.01Hz
(Note 3)
9999
84
34
Frequency jump 2B
0 to 400Hz,
9999
0.01Hz
(Note 3)
9999
84
35
Frequency jump 3A
0 to 400Hz,
9999
0.01Hz
(Note 3)
9999
84
36
Frequency jump 3B
0 to 400Hz,
9999
0.01Hz
(Note 3)
9999
84
37
Speed display
0,
0.01 to 9998
0.001 r/min
0
85
38
Frequency at 5V (10V) input
1 to 400Hz
0.01Hz
(Note 3)
50Hz
(Note 2)
86
St
andard operat
ion f
unct
ions
39
Frequency at 20mA input
1 to 400Hz
0.01Hz
(Note 3)
50Hz
(Note 2)
86
41
Up-to-frequency sensitivity
0 to 100%
0.1%
10%
87
42
Output frequency detection
0 to 400Hz
0.01Hz
(Note 3)
6Hz
88
Ou
tp
u
t
te
rm
inal
funct
ions
43
Output frequency detection
for reverse rotation
0 to 400Hz,
9999
0.01Hz
(Note 3)
9999
88
44
Second acceleration/
deceleration time
0 to 3600 s/
0 to 360 s
0.1 s/0.01 s
5 s/10 s
(Note 10)
73
45
Second deceleration time
0 to 3600 s/
0 to 360 s,
9999
0.1 s/0.01 s
9999
73
46
Second torque boost
(Note 1)
0 to 30%,
9999
0.1%
9999
69
47
Second V/F
(base frequency) (Note 1)
0 to 400Hz,
9999
0.01Hz
(Note 3)
9999
71
Second f
unct
ions
48
Second electronic thermal
O/L relay
0 to 500A,
9999
0.01A
9999
75
52
Control panel/PU main
display data selection
0,23,100
1
0
89
55
Frequency monitoring
reference
0 to 400Hz
0.01Hz
(Note 3)
50Hz
91
Display
f
unct
ions
56
Current monitoring reference
0 to 500A
0.01A
Rated
output
current
91
57
Restart coasting time
0 to 5 s,
9999
0.1 s
9999
92
A
u
to
m
a
ti
c
rest
art
funct
ions
58
Restart cushion time
0 to 60 s
0.1 s
1.0 s
92
Addit
ional
funct
ion
59
Remote setting function
selection
0, 1, 2
1
0
93
Parameter L
ist
4