Test operation and gain adjustment of the PM sensorless vector control
4.3.4
PM motor test operation (Pr. 800)
The above parameters can be set when
Pr. 160 Extended function display selection
= "0".
(1) Test operation
Setting
Pr. 800 Control method selection
= "9" will enable the PM motor test operation.
Perform a test operation by giving a speed and a start command under each of PU/External/Network operation mode.
Without connecting a PM motor, the speed movement can be checked by the monitor or analog signal output.
Two types of operation can be selected using this parameter: an actual operation by connecting a PM motor, or
a test operation without connecting a PM motor to simulate a virtual operation.
Parameter
Number
Name
Initial
value
Setting
range
Operation
800
Control method
selection
30
9
PM motor test operation (Motor is not driven even if it
is connected.)
30
Normal operation (Motor can be driven.)
REMARKS
· In the test operation, current is not detected and voltage is not output. Related monitor displays of the output current and
voltage show "0."
Time
Running speed
(FM output)
STF
RUN