155
Speed setting by analog input (terminal 2, 4)
(b) Method to adjust any point without application of a voltage (current) across terminals 2 and 5 (4 and 5)
(To change from 4V (80%) to 5V (100%))
Operation Display
1.
Confirm the operation status indicator and
operation mode indicator
The drive unit should be at a stop.
The drive unit should be in the PU operation
mode. (Use
)
2.
Press
to choose the parameter setting
mode.
PRM indicator is lit.
(The parameter number read previously appears.)
3.
Turn
until "
" appears.
4.
Press
to display "
".
5.
Turn
until "
" ("
") appears.
Set to
C4 Terminal 2 speed setting gain
.
Terminal 2 input is
selected
Terminal 4 input
is selected
6.
Press
to display the analog voltage
(current) value (%).
Analog voltage (current) value (%)
across terminals 2 and 5 (across
terminals 4 and 5)
7.
Turn
to set gain voltage (%).
"0V(0mA) is 0%, 10V(5V, 20mA) is 100%"
The gain speed is reached when
the analog voltage (current) value
across terminals 2 and 5 (across
terminals 4 and 5) is 100%.
8.
Press
to set.
Terminal 2 input
is selected
Terminal 4 input
is selected
Blink...Parameter setting complete!!
(Adjustment completed)
Turn
to read another parameter.
Press
to return to the "
" indication (step 4).
Press
twice to show the next parameter ("
").
REMARKS
By pressing
after step 6, you can confirm the current speed setting bias/gain setting.
You cannot check after performing operation in step 7.
C0 to C7 settings
are enabled.
REMARKS
The current setting at the instant of turning
is
displayed.
You cannot check after performing operation in step 7.
A
Summary of Contents for FR-D720-0.2K-G
Page 45: ...34 MEMO ...