![Mitsubishi Electric FR-D720-0.2K-G Instruction Manual Download Page 292](http://html.mh-extra.com/html/mitsubishi-electric/fr-d720-0-2k-g/fr-d720-0-2k-g_instruction-manual_239221292.webp)
289
Specifications of the S-PM geared motors
7.4.2
Motor torque characteristic
<<Initial setting (
Pr. 785
= 9999 (=100%))>>
In the low-speed range (less than 300r/min), the torque output can
be increased up to 100% of the setting, but continuous operation is
not possible.
When the input voltage is low, the torque may be reduced.
The operatable speed range at constant torque is 300r/min to
3000r/min.
Continuous operation cannot be performed in 300r/min or less.
<<When
Pr. 785
= 50%>>
Setting
Pr. 785 PM control torque boost
to 50%
or less enables
continuous operation at the speed less than 300r/min. However,
keep the short-time torque to
Pr. 785
setting or lower.
80% for the FR-D720-1.5K-G or lower and the FR-D740-1.5K-G or lower
When the input voltage is low, the torque may be reduced.
The operatable speed range at constant torque is 300r/min to
3000r/min.
150%
100%
50%
0
Torque
Continuous operation range
Short time (60s) operation range
300r/min
3000r/min
Motor rotation speed
150%
100%
50%
0
Torque
300r/min
3000r/min
Motor rotation speed
Continuous operation range
Short time (60s) operation range
Summary of Contents for FR-D720-0.2K-G
Page 45: ...34 MEMO ...
Page 293: ...290 MEMO ...