Communication operation and setting
[Drive unit status monitor]
The signal is the initial setting. The description changes depending on the
Pr. 190, Pr. 192 (output terminal function selection)
.
[Multi command (HF0)]
Sending data format from computer to drive unit
Reply data format from drive unit to computer (No data error detected)
Specify the data type of sending data (from computer to drive unit).
Specify the data type of reply data (from drive unit to computer).
Combination of data 1 and data 2 for sending
Combination of data 1 and data 2 for reply
Error code for sending data 1 is set in error code 1, and error code for sending data 2 is set in error code 2.
Mode error (HA), instruction code error (HB), data range error (HC) or no error (HF) is replied. (
Refer to page 195
for more details of the error codes.)
Item
Instruction
Code
Bit
Length
Description
Example
Drive unit
status
monitor
H7A
8 bits
b0: RUN (drive unit running (Variable))
b1: Forward rotation (Fixed)
b2: Reverse rotation (Fixed)
b3: up-to-speed (Fixed)
b4: overload (Fixed)
b5: —
b6: speed detection
(Fixed)
b7: ABC (fault (Variable))
Drive unit
status
monitor
(expansion)
H79
16 bits
b0: RUN (drive unit running (Variable))
b1: During forward rotation (Fixed)
b2: During reverse rotation (Fixed)
b3: up-to-speed (Fixed)
b4: overload (Fixed)
b5: —
b6: speed detection
(Fixed)
b7: ABC (fault (Variable))
b8 to b14: —
b15: Fault occurrence
Format
Number of Characters
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
A3
ENQ
Drive unit
station
number
Instruction
code
(HF0)
Waiting
time
Send
data
type
Receive
data
type
Data2
Sum
check
CR/LF
Format
Number of Characters
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
C1
STX
Drive unit
station
number
Send
data
type
Receive
data
type
Error
code 1
Error
code 2
Data1
Data2
ETX
Sum
check
CR/LF
Data Type
Data 1
Data 2
Remarks
0
Run command
(extended)
Set speed (RAM)
Run command (expansion) is same as instruction code HF9
(
.)
The unit of set speed (frequency) is always by four digits, even
when "0.01 to 9998" is set in
Pr. 37
and "01" is set in instruction
code HFF.
1
Run command
(extended)
Set speed
(RAM,
EEPROM)
Data Type
Data 1
Data 2
Remarks
0
Drive unit status
monitor (extended)
Rotation speed
(Output frequency)
Drive unit status monitor (expansion) is same as instruction code
H79 (
Rotation speed (frequency) monitor is in 1 increments. (Numbers
after the decimal point are rounded.)
Replies the monitor item specified in instruction code HF3 for
special monitor.(
1
Drive unit status
monitor (extended)
Special monitor
0
0
0
0
0
0
1
1
b7
b0
[Example 1] H03... During forward rotation
[Example 2] H80... Stop at fault occurrence
1
0
0
0
0
0
0
0
b7
b0
0
0
0
0
0
0
1
1
b0
0
0
0
0
0
0
0
0
b15
[Example 1] H0003... During forward rotation
1
0
0
0
0
0
0
0
b0
1
0
0
0
0
0
0
0
b15
[Example 2] H8080... Stop at fault occurrence
Summary of Contents for FR-D720-0.2K-G
Page 45: ...34 MEMO ...
Page 293: ...290 MEMO ...