-
130
-
'11 • PAC-T-160
2) Model FDC100VS, 125VS, 140VS
a) Replace the PCB
after elapsing 3 minutes from power OFF
.
(
Be sure to measure voltage (DC)
on both capacitor terminals located in controller back, and
check that the
voltage is discharged sufficiently
.(Refer to Fig.1))
b) Disconnect the connectors from the control PCB.
c) Disconnect the white wiring passing through CT1 on the PCB before replacing the PCB.
d) Match the setting switches (SW3-5,JSW) with the former PCB.
e) Tighten up a screw after passing white wiring through CT1 of the changed.
f) Connect the connectors to the control PCB.(Confirm the
connectors are not half inserted
.)
after elapsing 3 minutes
from power OFF
connectors are not half
inserted
Parts No.
Parts arrangement view
CNA2
CNIP
CNTH
CNPS
CNI1
CNI3
CNA1
CNFAN1
CNEEV2
CNEEV1
CNS
CNR
CNH
CNW
CNW2
JSW
SW5
SW4
SW3
CNB
CT1
CNM
Fig.1 Position of capacitor
Voltage measurement parts
PCA012D024C
C
Summary of Contents for FDF100VNVD
Page 81: ... 80 80 11 PAC T 160 ...
Page 82: ... 81 81 11 PAC T 160 ...
Page 83: ... 82 82 11 PAC T 160 ...