Automatic restart after
instantaneous power
failure
No startup waiting time.
Using the regeneration avoidance function together
is recommended.
Startup waiting time exists.
Startup delay
Startup delay of about 0.1s for initial tuning.
No startup delay.
Driving by the
commercial power
supply
Not available.
Never connect an IPM motor to the commercial
power supply.
Can be driven by the commercial power supply.
Operation during
coasting
While the motor is coasting, potential is generated
across motor terminals.
Before wiring, make sure that the motor is stopped.
While the motor is coasting, no potential is generated
across motor terminals.
Maximum motor wiring
length
FR-F740PJ-0.4K.............................. 50m or shorter
FR-F720PJ-0.4K to 15K,
FR-F740PJ-0.75K to15K ................. 100m or shorter
500m or shorter in total
NOTE
No slippage occurs with an IPM motor because of its characteristic.
If an IPM motor, which took over a general-purpose motor, is driven at the same speed as for the general-purpose
motor, the running speed of the IPM motor becomes faster by the amount of the general-purpose motor's slippage.
Adjust the speed command to run the IPM motor at the same speed as the general-purpose motor, as required.
Item
IPM motor control
General-purpose motor control